Area Partitioning - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P42e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
2e ON: Zone 2 is a Handover zone.
notes
• When a zone is selected for this type, it
is automatically deselected from any other
zone type in the DelAy GROUP .
P43e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All OFF: No zones have entry Delay2.
notes
P44e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All ON: All zones are lockout zones.
notes
• The SIREN output always locks out.
• 0e will turn all selections OFF.
MeMory e will turn all selections ON.
relAteD oPtions
P60e 4e Tamper Reset lockout.
P78e Multiple alarm reports.

AreA PArtitioning

P45e, P46e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
No zones assigned to Area 2.
notes
• For options P45E and P46E, [Zone no] e
toggles the selection ON and OFF.
• Zones assigned to BOTH areas
become Common zones.
• If no Area operation is required, assign
all zones to Area 1. (This is also the
factory default).
HAnDoVer Zones
Handover zones are delayed only if entry is made through an entry Delay zone first.
If a Handover zone is triggered first, the zone behaves as an instant zone. Normally,
the "point of entry" zone should be Delay zone, with any other zones in the entry path
programmed as Handover zones.
PROGRAMMING SeQUeNCe:
P42e [Zone no]e turns the options ON
P42e [Zone no]e on: the zone is a Handover zone
to deselect the option, select a different zone type in the DeLaY grouP .
entry DelAy2 Zones
When an entry Delay2 zone is triggered, it has entry delay as set by the entry Delay
Time2 (P27e).
PROGRAMMING SeQUeNCe:
P43e [Zone no]e turns the options ON
P43e [Zone no]e on: the zone is an entry Delay2 zone
to deselect the option, select a different zone type in the DeLaY grouP .
reset loCkoUt Zones
All zones and tamper input can be programmed to lockout, i.e. cause the ReSeT
OUTPUT to sound only once while the panel is armed.
The ReSeT OUTPUT is then locked out for that alarmed zone until entering a valid
code has reset the panel. If using area partitioning, disarming either partition resets the
zone lockout for both partitions.
PROGRAMMING SeQUeNCe:
P44e [Zone no]e toggles the options ON and OFF
P44e [Zone no]e oFF: the zone is not a Lockout zone
P44e [Zone no]e on: the zone is a Lockout zone
Assigning Zones to AreAs
Option No.
Description
P45e
AReA 1 ZONeS
P46e
AReA 2 ZONeS
Assigning Zones to AreAs
Assign (or remove) zones that will operate in Area 1 and/or Area 2.
PROGRAMMING SeQUeNCe:
P45e [Zone no]e toggles the options ON and OFF for Area1
[Zone no] oFF: the zone is not in area1
[Zone no] on: the zone is in area1
P46e [Zone no]e toggles the options ON and OFF for Area2
[Zone no] oFF: the zone is not in area2
[Zone no] on: the zone is in area2
exAMPle:
To program zones 1–4 for Area 1 and zones 1, 5–8 for Area 2.
In this example, we have assigned zone 1 to both areas, so it becomes a Common
Zone.
P45e use the [Zone no] e sequence to turn on only zones 1–4.
P46e use the [Zone no] e sequence to turn on zone 1 and zones 5–8.
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g
ZONeS 1–8 (D8 & D16)
1
2
3
4
5
6
7
8
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ZONeS 9–16 (D16)
9 10 11 12 13 14 15 16
19