P155e, P156e, P157e, P158e
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
20 sec.
relAteD oPtions
P151e 8e Pulse AUX5
P152e 8e Pulse AUX6
P153e 8e Pulse AUX7
P154e 8e Pulse AUX8
P160e
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
level 99 (highest)
P161e
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
level 99 (highest)
P162e
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
level 16 (low volume)
AUx5, AUx6, AUx7, AUx8 OUTPUT OPTIONS
AUx5 – AUx8 timers
Sets the length of pulse time for the AUX5 – AUX8 outputs when the outputs are set for
Pulse mode. Select 1 to 99 seconds.
TO PROGRAM
Press P155e, P156e, P157e or P158e (The existing Pulse Time will be displayed).
Press [NeW TIMe] e (The new Pulse Time will be displayed).
AlArm siren VolUme
Sets the Audible Alarm volume level for the Siren output.
Select volume from 1 (lowest) to 99 (highest).
TO PROGRAM
Press P160e (The existing volume level will be displayed).
Press [NeW leVel] e (The new level will be displayed).
Fire siren VolUme
Sets the Fire Alarm volume level for the Siren output.
Select volume from 1 (lowest) to 99 (highest).
TO PROGRAM
Press P161e (The existing volume level will be displayed).
Press [NeW leVel] e (The new level will be displayed).
CHirP siren VolUme
Sets the Chirp volume level for the Siren output.
Select volume from 1 (lowest) to 99 (highest).
TO PROGRAM
Press P162e (The existing volume level will be displayed).
Press [NeW leVel] e (The new level will be displayed).
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Option No.
Description
P155e
AUX5 TIMeR
P156e
AUX6 TIMeR
P157e
AUX7 TIMeR
P158e
AUX8 TIMeR
Option No.
Description
P160e
AlARM SIReN VOlUMe
P161e
FIRe SIReN VOlUMe
P162e
CHIRP SIReN VOlUMe
P r o g r A m m i n g
Default
Note
20 sec
1 to 99 seconds
20 sec
1 to 99 seconds
20 sec
1 to 99 seconds
20 sec
1 to 99 seconds
Default
Note
99
1 to 99 levels
99
1 to 99 levels
16
1 to 99 levels
67