Autotime Description And Examples - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

AUto-time FeAtUres
D8x/D16x V6 onwards features sophisticated new automation features making full use of the onboard Real Time Clock
and a set of powerful yet simple to program options.
ARMED
ARMED
HOME
exAmPle 1
AReA 1 to Auto Arm Monday to Friday at
6:30pm with warning beeps 10 minutes prior
to the event.
The keypad will start a slow continuous beep
at 6:20pm, then at 6:29pm the beeps change
to a faster rate for the final minute.
TO SIleNCe THe BeePS during the warning
period. Pressing any key on the keypad will
stop the beeps on the keypad (and the Reset
output) and then start again for the final
minute with a slightly faster beep.
TO DelAy ARMING enter a valid user code
on its own. (The user code must be assigned
to an Area to work). This will turn off the
warning beeps and the Auto Arm for 1 hour
- when the warning process will start again.
Programming steps
Autotimer 1
P350e
Minutes 0-59
P351e
Hours 0-23
P352e
Days (1=Sunday)
1e
AReA 1 ARM
P353e
6e
KeyPAD Beeps
8e
extend AutoTIMe
P390e
AutoTime warning
In this example, if reporting to a central
station, the arming will be sent as User 91.
1. For correct operation of Auto-Time features please ensure that the onboard clock is set to the current time and
date. See option P340-P345e, page 70.
2. D8/D16 version 8 and later has a real time clock onboard which does not rely on external timing signals.
ARM or DISARM AUTOMATICAlly at pre-programmed times of day or day of the week.
This feature can save a site manager many headaches and hours of travel time. There is
no need to rely on staff remembering to arm or disarm the system.
TURN OUTPUTS ON or OFF at pre-programmed times - every day, once a week,
anytime. Automate doors, sprinkler systems, lights and more.
eNABle/DISABle USeR CODeS depending on the time of day or day of the week. Allows
managers to grant users access to the system at selected times and deny after hours entry.
This applies to keypad codes only, not radio keys or prox fobs.
exAmPle 2
AUX1 turns on for one minute every
Saturday at 8pm.
This could be used to turn on sprinkers,
a pool or spa pump, lights or anything
that can be triggered by a relay output.
(Requires optional 106-013 Four Relay
Board).
Programming steps
Autotimer 2
P355e
P356e
P357e
P359e
6e
P145e
TIp 1. The output can also be pulsed
on (or toggled on/off) anytime using
30
the 11* or 11# keypad commands.
18
See page 11.
2, 3, 4, 5, 6
ON
TIp 2. For longer periods (up to a
ON
week), a pair of AutoTimers can be
ON
used - one to turn the AUX ON & the
other to turn it OFF.
10
The power and flexibility of AutoTime means it has numerous programmable options
which makes nessComms software the ideal programming tool.
The NessComms graphical user interface makes it easy to program complex options
on your PC or laptop. Then simply connect and download.
NessComms makes your life easier! See page 4 for further information.
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
exAmPle 3
User Code 56 is programmed to work only on
Monday-Friday between 7am to 5pm.
The user code will be disabled outside of
these times. (Applies only to keypad codes.
Radio keys and prox fobs will work anytime
regardless.)
Programming steps
Enable Extra Option 9E for user code 56 to
enable the user code for use by AutoTime.
Minutes 0-59
00
eXClUDe+e toggles extra Options
mode. See page 15.
Hours 0-23
20
Days (1=Sunday)
7
P256e
AUX1 PUlSe
ON
AutoTimer 3 Enables the user code.
AUX1 Pulse Time
60
Autotimer 3
P360e
P361e
P362e
P363e
AutoTimer 4 Disables the code.
Autotimer 4
P365e
P366e
P367e
P368e
AUtomAtion
FeAtUres
9e
enable user Code
for AutoTime
User Code 56
ON
Minutes 0-59
00
Hours 0-23
07
Days (1=Sunday)
2, 3, 4, 5, 6
4e
Code enable
ON
Minutes 0-59
00
Hours 0-23
07
Days (1=Sunday)
2, 3, 4, 5, 6
5e
Code Disable
ON
69
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D16xd

Table of Contents