P88e 5e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Forced opening Reports enabled
notes
• This option is used to indicate to the
Central Station that an alarm has been
reset by a valid user.
Usually used in cases where Open/Close
reports are normally selected OFF.
P88e 6e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Closing Reports sent on Arming.
relAteD oPtions
P88e 1e AReA1 Open/Close reports.
P88e 2e AReA2 Open/Close reports.
P88e 7e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Manual exclude Reports enabled.
relAteD oPtions
P88e 8e Auto exclude Reports.
P88e 8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Auto exclude Reports enabled.
relAteD oPtions
P88e 7e Manual exclude Reports.

ForCeD oPening rePort

If Forced Opening Report is selected ON – when an alarm has been reset by a valid
User Code (or Radio Key), the dialler will send an Opening report along with a restoral
report for the zone or miscellaneous input which caused the alarm.
PROGRAMMING SeQUeNCe:
P88e 5e toggles the option ON and OFF
oFF: no Forced opening reports
on: Forced opening reports enabled
DelAy Closing rePort
If selected ON, Closing reports (if enabled) are sent at the end of exit Time. Normally,
Closing reports are sent immediately on arming.
PROGRAMMING SeQUeNCe:
P88e 6e toggles the option ON and OFF
oFF: Closing reports sent on arming
on: Closing reports sent at end of exit time
mAnUAl exClUDe rePort
enables Manual exclude Reports for zones. exclude Reports for 24hr zones are sent
on exiting eXClUDe mode.
PROGRAMMING SeQUeNCe:
P88e 7e toggles the option ON and OFF
oFF: no Manual exclude reports
on: Manual exclude reports enabled
AUto exClUDe rePort
enables Auto exclude Reports for Zones. Zones not sealed on arming will be reported
as Auto excluded..
PROGRAMMING SeQUeNCe:
P88e 8e toggles the option ON and OFF
oFF: no auto exclude reports
on: auto exclude reports enabled
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g
47