Aux2 Output Options - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P142e 1e – 8e
Available in D8x/D16x V6 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
All off.
notes
Any or all options may be selected on.
P142e 1e
P142e 2e
P142e 3e
P142e 4e
P142e 5e
notes
Remote operation by telephone
procedure as detailed in the user and
installation manuals must be followed
before access is allowed. This includes
entering a valid user code.
relAteD oPtions
P90e 5e, enable remote Aux control.
P142e 8e
relAteD oPtions
P146e, AUX2 Pulse Time.
P146e
Available in D8x/D16x V6 and later.
ProgrAm moDe leVel
Installer mode or NessComms V5.3
or later.
FACtory DeFAUlt
20 sec.
relAteD oPtions
P142e 8e

AUx2 OUTPUT OPTIONS

enHAnCeD AUx2 oUtPUt oPtions
The P142e enhanced AUX2 options work along with P122e and AutoTimers to provide
multiple choices of events and alarms to control AUX2.
TO PROGRAM
1. Press P142e.
2. Press 1e ... 8e to turn an option on. Multiple options can be selected.
AreA1 ArmeD to AUx2
Turns on AUX2 while Area 1 is armed.
AreA2 ArmeD to AUx2
Turns on AUX2 while Area 2 is armed.
Home ArmeD to AUx2
Turns on AUX2 while armed in Home mode.
keyPAD toggle AUx2
When this option is on,
AUX2 is turned ON or PUlSeD with the keypress 22* (* = left hand STAR button).
AUX2 is turned OFF with the keypress 22# (# = Right hand STAR button).
telePHone remote Control oF AUx2
When this option is on,
AUX2 is turned ON or PUlSeD with the telephone keypress 22*
AUX2 is turned OFF with the telephone keypress 22#
FeeDbACk tones HeArD by PHone:
3 BeePS: The AUX has been turned ON or is already ON.
1 BeeP: The AUX has been turned OFF or is already OFF.
1 lONG BeeP: error. Remote AUX operation by telephone is not enabled.
PUlse AUx2
This option converts the P122e 1e and the P142e 1e, 2e, 3e, 4e, 5e options into a pulsed
AUX2 output.
AUX2 is pulsed on for the time set in P146e.
Option No.
Description
P146e
AUX2 TIMeR
AUx2 timer
Sets the length of pulse time for the AUX2 output when the P142e 8e option is selected.
Select 1 to 99 seconds.
TO PROGRAM
Press P146e (The existing Pulse Time will be displayed).
Press [NeW TIMe] e (The new Pulse Time will be displayed).
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
P r o g r A m m i n g
Default
Note
20 sec
1 to 99 seconds
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D16xd