Operation Summary - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

OPeRATION
to Arm
The panel must initially be
disarmed.
to DisArm
To disarm and/or reset alarms.
to arm Home moDe
Area1 must initially be
disarmed.
Home Mode can be used if
the panel is fully disarmed or if
only Area2 is armed, see page
20 for more information.
PAniC alarm
keyPAD DUress
Keypad Duress allows the user
to send a silent duress report
while disarming, (if the system
is being monitored by a central
station).
exClUDe Zones
eXClUDe + e can only
be used when the panel is
disarmed.
eXClUDe + CODe + e can be
used anytime.
oPerAte AUx
oUtPUts
The AUX outputs must be
enabled for operation by
keypad. See P141e 4e, P142e
4e, P143e 4e, P144e 4e.
* If a user code is assigned to a radio key and has extra Option 4e enabled, (Code Only arming), then pressing OFF toggles the panel arm/disarm state.
temPorAry DAy Zone (tDZ) operation
While remaining in normal operating mode, the user can add and remove Temporary Day Zones and enable/disable day zone operation.
The panel must initially be
disarmed.
P64e 2e must be on to enable
the use of Temporary Day
Zones.
See page 20 for more
information on Temporary Day
Zones.
by keyPAD
+
Press
(If the Arming Shortcut is enabled, P62e 5e)
+
[User Code]
or press
[User Code]
+
or press
(If Code Only Arming has been enabled for
that user code. extra Option 4e)
[User Code]
+
Press
+
Press
(If the Home Shortcut is enabled, P62e 3e)
+
[User Code]
or press
Press
keys together
+
[User Code]
or press
+
or press
(If Keypad Panic Shortcut is enabled, P62e 4e)
[5, 6, 8 or 9]+[User Code]
Press
Add one these digits in front of a user code when disarming.
This sequence will disarm the panel and send a Duress report by dialler to the central station.
(Report Keypad Duress must be enabled, P75e 1e)
+
Press
(If the exclude Shortcut is enabled, P62e 2e)
+
[Zone No.]
[Zone No.]
then
then press
to exit exclude mode
The exclude light flashes constantly while zones are excluded. excluded zones are automatically
Included next time the panel is disarmed.
Press
to turn ON or PUlSe AUx1.
Press
to turn ON or PUlSe AUx2.
Press
to turn ON or PUlSe AUx3.
Press
to turn ON or PUlSe AUx4.
+
Press
To enter TDZ Selection Mode.
[Zone No.]
then press
then press
To save changes and exit TDZ Selection Mode.
+
Press
To enable/disable TDZ operation.
Temporary Day Zone mode enabled is indicated by the Home icon flashing.
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
by rADio key
+
Press the ON button once.
Press the OFF button once.*
Press either the OFF
button or the ON button
twice within 4 seconds.
(P69e 5e must be on).
+
Radio Key Home Arm chirps can be enabled by
P120e 2e. Radio Key Home Arm strobe flash can
be enabled by P64e 6e, (off by default).
+
+
+
(enter the zone number/s to be excluded.)
Press
Press
Press
Press
+
To select one or more zone to be Temporary Day Zones.

oPerAtion sUmmAry

by ACCess CArD or Fob
Present a Card or Fob
twice. (if P301e 2e is
on).
Or, present a Card
or Fob once + press
button. (if P301e 3e
is on).
Present a Card or Fob
once. (if P301e 4e is
on).
Or press the AUX but-
ton once. (If P120e 3e
is on). RK4 radio key
only.
Press and hold the PANIC
button for at least 4 sec.
If P68e 1e Double Press
Radio Panic is enabled,
press and hold twice for 4
sec.
to turn OFF.
to turn OFF.
to turn OFF.
to turn OFF.
11