Swinger Shutdown; Line Fault Monitor - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P89e 4e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Swinger Shutdown enabled.
notes
This prevents unnecessary multiple
alarms reported to the Central station
in cases, for example, where a door is
'swinging' in the wind.
This option only applies to zones enabled
to Report Multiple Zone Alarms.
relAteD oPtions
P78e Report Multiple Zone Alarms.
P89e 5e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No line Fault Monitor.
relAteD oPtions
P122e 5e line Fault to AUX2.

sWinger sHUtDoWn

limits the number of calls made by a zone alarm in any one armed period.
Alarm reports are normally limited to 15 multiple reports per zone.
When Swinger Shutdown is enabled, multiple reports are reduced to 3 multiple reports
per zone.
PROGRAMMING SeQUeNCe:
P89e 4e toggles the option ON and OFF
oFF: Swinger Shutdown is 15 reports per zone
on: Swinger Shutdown is 3 reports per zone

line FAUlt monitor

When this option is enabled, the telephone line is regularly tested. If the telephone line
is not found, the line light will commence flashing.
PROGRAMMING SeQUeNCe:
P89e 5e toggles the option ON and OFF
oFF: no Line Fault Monitor
on: Line Fault Monitor enabled