P r o g r A m m i n g
P63e 1e–4e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
1e, 2e, 3e ON.
4e OFF.
relAteD oPtions
P64e 1e Brief Home alarm.
P63e 5e–8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
5e ON.
6e, 7e, 8e OFF.
relAteD oPtions
P64e 2e Brief Day alarm.
For Zone to oUtPUt mAPPing for
armed & 24hr states – see options
P54e – P59e, page 22-23.
28
Option No.
P63e
1e
2e
3e
4e
5e
6e
7e
8e

Home moDe oUtPUt mAPPing

This option selects which outputs are triggered by alarms in Home Mode.
PROGRAMMING SeQUeNCe:
P63e 1e–4e toggles the options ON and OFF
1e on: Home Mode to reset output
2e on: Home Mode to Strobe output
3e on: Home Mode to Keypad Sonalert output
4e on: Home Mode to Siren output

DAy moDe oUtPUt mAPPing

This option selects which outputs are triggered by alarms in Day Mode.
PROGRAMMING SeQUeNCe:
P63e 5e-8e toggles the options ON and OFF
5e on: Day Mode to reset output
6e on: Day Mode to Strobe output, (if Brief Day alarm is enabled, (P64e 2e), then this option
sends day alarms to the auX2 output).
7e on: Day Mode to Keypad Sonalert output
8e on: Day Mode to Siren output
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Description
Home Mode alarms to ReSeT output
Home Mode alarms to STROBe
Home Mode alarms to SONAleRT
Home Mode alarms to SIReN
Day Mode to ReSeT output
Day Mode to STROBe
Day Mode to keypad SONAleRT
Day Mode to SIReN
Default
ON
ON
ON
OFF
ON
OFF
OFF
OFF