Supervision Time - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P66e 5e
tHis oPtion is AVAilAble in
D8x/D16x V5.2 AnD lAter
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Radio Zone Supervision enabled.
relAteD oPtions
P65e Supervised Zones.
P66e 1e–4e Supervision Alerts.
P66e 5e Wired Zone Supervision.
P67e Zone Supervision Time.
P92e 4e (D8) Report Supervision.
P75e 12e (D16) Report Supervision.
P66e 7e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Supervision Time normal.
relAteD oPtions
P67e Supervision Time.
P66e 8e Supervision Time speedup
x10.
P66e 8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Supervision Time normal.
relAteD oPtions
P67e Supervision Time.
P66e 7e Supervision Time speedup
x6.
P67e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
24 hours or 24 minutes.
notes
• Supervision time for wired or wireless
zones must be 2 minutes or greater for
correct operation.
• A setting of less than 3 hours for radio
supervision is not recommended.
• The Supervision timer is reset on exit
from Installer Program Mode and on Arm
or Disarm.
relAteD oPtions
P65e Supervised Zones.
P66e 1e–4e Supervision Alerts.
P66e 7e–8e
Supervision Time Speed-up.
enAble WireD Zone sUPerVision
This option enables Wired Zone Supervision or Radio Zone Supervision.
PROGRAMMING SeQUeNCe:
P66e 5e toggles the option ON and OFF
oFF: radio Zone Supervision enabled
on: Wired Zone Supervision enabled
sUPerVision time sPeeDUP x6
Setting this option speeds up the Supervision Time by 6. For instance if P67e is set to
1 hour (60 minutes), then this option will reduce it to 10 minutes. (i.e., 60 divided by 6).
PROGRAMMING SeQUeNCe:
P66e 7e toggles the option ON and OFF
oFF: Supervision time normal as set by P67e
on: Supervision time speedup x6
sUPerVision time sPeeDUP x10
Setting this option speeds up the Supervision Time by 10. For instance if P67e is set to
1 hour (60 minutes), then this option will reduce it to 6 minutes. (i.e., 60 divided by 10).
PROGRAMMING SeQUeNCe:
P66e 8e toggles the option ON and OFF
oFF: Supervision time normal as set by P67e
on: Supervision time speedup x10

sUPerVision time

SUPeRVISION TIMe sets the time interval before an inactive Supervised Zone triggers
a Supervision alarm.
The SUPeRVISION TIMe setting is from 01 to 24 hours.
For timing up to 24 minutes, set P66e 7e & 8e on.
For timing up to 24 hours, set P66e 7e & 8e off.
PROGRAMMING SeQUeNCe:
P67e existing time is displayed one digit at a time
[enTer neW TiMe] e new time is displayed one digit at a time
exAMPle: To program SUPerViSion TiMe to be 4 hours:
P67e 04e
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
NOTe: If both P66e 7e and 8e are both ON then the Supervision
time is sped up by 60. For instance if P67e is set to 1 hour (60
minutes), then this option will reduce it to 1 minute. (i.e., 60
divided by 60).
P r o g r A m m i n g
33