esD WArning
(electrostatic Discharge).
Once properly installed, Ness control
panels are well protected from eSD.
However, take note of the following
precautions during installation.
The human body can generate static
electricity when it is insulated from earth
- for instance by walking over carpet.
eSD occurs (and a small shock is
sometimes felt) if an earthed metal
object is then touched.
The installer should be aware that if
he generates static electricity while
installing the panel and then discharges
this static electricity into the internal
components on the main D8/D16 circuit
board or the keypad board, then eSD
damage may occur.
The circuit board should not be
unwrapped until it is actually ready to be
installed.
Methods to avoid electrostatic build-up.
1.
Use a foot strap, a wrist strap,
or a grounding mat. The aim is
to connect the body to earth to
discharge static before it builds up.
The connection is a high resistance
for personnel safety.
2.
If the above is not available, then it
is advisable to wear clothing that will
minimise the build-up of static.
3.
Handle circuit boards by the edges.
Avoid touching any components on
the board as the integrated circuits,
in particular, are not guaranteed by
their manufacturers to be safe from
eSD.
4.
To minimise the build-up of static,
D8 MAIN BOARD
avoid walking around as much
as possible while working on the
installation.
5.
Touch an earthed object to
LISTEN PINS
discharge any static before working
Diagnostics. Connect an
on the installation.
8 Ohm horn speaker to
listen to dialler tones.
J1 LINK
RECEIVER
BOX TAMPER
Header for
connecting
optional Radio
Interface.
Power up with link off to enter
installer program mode
AUX1
AUX
AUX2
Aux outputs
AUX3
1-4.
AUX4
+12V
0V
SERIAL
Rs232 serial port
READER
Connection for
up to 3 Ness
Weigand readers
Insert the white N/C tamper switch
BATTERY LEADS
(supplied)
BLACK
RED +
BATTERY CONNECTION
Backup battery holder.
For 12V 7Ah backup
Suits up to 12V 7Ah battery.
battery (BAT210)
N
ess
RADIO INTERFACE
Part No. 100-200
6
TO
RECEIVER
HEADER

instAllAtion ProCeDUres

The main panel housing and keypad/s should be installed within areas that are
protected by motion sensors or reed switches. A linen closet or cupboard are good
examples as these are generally located in the centre of the premises. Installing in
ceiling spaces or other areas where extremes of temperature may be encountered is
not advised.
Positioning of the movement detectors should be considered as the incorrect position
may cause unwanted alarms. Refer to the motion sensors' installation instructions.
1. Remove the lid and the battery from the base.
2. Securely mount the rear panel housing in a secure location.
3. Run all cabling needed for the installation.
4. Insert the red PCB stand-offs in the housing and then plug the circuit board onto
the stand-offs. See the eSD Warning on this page.
5. Wire the sensors, sirens and accessories to the main board terminal blocks as per
the wiring instructions shown in this installation manual.
6. Fit the battery into the housing but DO NOT CONNeCT the battery yet.
7. Insert the panel tamper bracket leads as shown below.
8. Power up as described below.
9. Close the lid and program the panel as required.
PoWer-UP ProCeDUre
To enter INSTAlleR PROGRAM MODe the first time, power-up with the PROG/TAMP
link OFF. If the PROG/TAMP link is ON and any other 24hr zones are unsealed on
power-up the panel will immediately go into alarm - reset the alarm via keypad or
remove power to stop the alarm.
1. ConneCt tHe bAttery First. Observe correct polarity.
a) The heartbeat leD will flash continuously to indicate correct operation.
b) The Current limiting Globes should be OFF. If the Globes are glowing, the
TELEPHONE LEAD (Supplied)
battery connection is reversed. Immediately disconnect the battery and check the
Connect to Mode3 socket
polarity of the battery leads.
Lead shown is for Australia only.
If the heartbeat leD does not flash steadily or cycles off intermittently there may be a
problem with the initialisation of the onboard memory. to remedy, in installer Program
mode press P95e, P97e & P98e to erase all programming and reload factory defaults.
Then remove power by briefly removing one of the battery leads then re-connect. The
TAMP
heartbeat leD should now be flashing continuously, proceed to step 2.
0V
TELEPHONE
+12V
Z8
2. tUrn on tHe externAl PoWer sUPPly. The Current limiting Globes may
C
glow slightly to indicate that the battery is charging correctly.
Z7
Z6
C
NOTe:
Z5
your panel has a dual 17VAC/20VDC power input.
Z4
Please use the correct power supply as shown on
page 8
&
PROGRAM LINK
C
= Sealed, normal state
Z3
= Tamper alarm state
Z2
C
Z1
0V
+12V
DAT
CLK
BOX TAMPER
COM
SWITCH
N.C. Contacts
+12V
(WHITE)
RESET
STR
"HEARTBEAT" LED
Constantly flashes
SIREN
AC
17V
AC
EARTH
HEATSINK
N
ess
RELAY BOARD
Part No. 106-013
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
0V
N.O TAMPER SWITCH
(761-002) Colour: BLACK
Supplied with Ness siren covers
12V DC output
END OF LINE RESISTORS
Zone 8
2k2
The default end of line resistor value is 2k2 (2200 Ohms). The EOL value
2k2
Zone 7
is fully programmable with a choice of 13 resistor values, see program
option P129E.
Zone 6
Ness panels are supplied with 2k2 1% tolerance Metal Film resistors.
2k2
Colour code: Red, Red, Black, Brown, Brown.
2k2
Zone 5
ZONE WIRING
Zone 4
2k2
NORMALLY CLOSED
(
N.C.)
2k2
Zone 3
Zone 2
2k2
NORMALLY OPEN
(
N.O.)
Zone 1
2k2
12V DC output for detectors. Auto Reset fuse protected.
500mA max. from all 12V outputs.
DAT
CLK
COM
+12V
17V AC
(White & Black)
EARTH
(Yellow/Green stripe)
OPTIONAL ACCESSORIES FOR D8 & D16
Ness OUTPUT EXPANDER
WEIGAND READER INTERFACE
Part No. 106-011
Part No. 106-012
To Aux Header
ALTERNATIVE TAMPER SWITCH WIRING
For N.C. Tamper Switches
N.C TAMPER SWITCH (SWI920) Colour: WHITE
Zone
C
DEVICES
Zone
DEVICES
C
NESS LCD Keypad
Maximum
3 keypads
Up to 2 x Ness 12V Siren (100-172)
OR 3 x 12V Screamer (100-238, 100-004)
Up to 2 x Strobe Light (NOI-300)
Up to 3 x Horn Speaker, 8 Ohm (NOI-110)
Ness 17V AC Plug Pack
(Australia only)
X
X
N
ess
SERIAL CABLE
Part No. 450-185
To
READER
header
To
header
ZONES 1-8
17VAC or
20VDC
Power InPut
ZONES 1-8
non-PolArIty
Insert the four red PCB
posts in the positions
shown
D8XD or D16XD
pcb
SERIAL