FACtory DeFAUlts
Master Code: 123
Installer Code: 000000
instAller ProgrAm moDe
Installer Program Mode allows access to All
program options.
note1. When in Installer Program Mode the
the panel will answer all incoming telephone
calls. This allows NessComms to connect via
dial-up.
NessComms Direct Connect via the serial
port also requires the panel to be in Installer
Program Mode.
note2. The panel will remain in Installer
Program Mode until
P + e is entered by keypad.
instAller's PoWer tiP
All inputs are disabled while the panel is in
Installer Program Mode. This handy feature
allows you to work on the system without
triggering 24 hour zones such as tamper
inputs.
User ProgrAm moDe
User Program Mode allows the owner to program:
• All User Codes
• Entry Exit Times
• Follow Me Telephone number
• Real Time Clock settings
Note: The panel will automatically drop out of
User Program Mode to Operating Mode if no
keypad buttons are pressed for 4 minutes.
HoW to ProgrAm A PAnel Using ness PD
The Ness PD Portable Download tool copies and loads data from panel to panel using the ReADeR header on D8x & D16x
panels.
Requires D8x/D16x version 7.4 or later.
From Panel to PD
From PD to Panel
Notes:
1. A NessPD can store defaults for both a D8x and a D16x at the same time. NessPD auto-recognises the panel type and will not copy D8x options into
a D16x (or vice versa). Repeat steps 1 to 5 to copy data from both panels.
2. The ReADeR header is normally used for access control. your 106-012 Weigand Interface, if installed, can be temporarily disconnected while using
NessPD.
3. The PROTeCT link prevents the NessPD from being overwritten.
4. If The GReeN indicator does not come on, then the NessPD is not connected to the panel. If it comes on briefly then the NessPD is Protected or has
no data for that panel model or the data is not compatible (the program option list is different).
5. If the PROTeCT link is not installed, any further programming changes made to the panel will be copied to the NessPD.
ProgrAm leVels FloW CHArt
1. The panel should be in installation Program mode.
2. Connect the NessPD to the ReADeR header on the panel.
3. Remove the PROTeCT link on the NessPD.
4. Press P+e to exit installation Program mode. At this stage, all panel programming options
will be automatically copied to the NessPD. The green leD on the NessPD will turn on for 2sec
to indicate the data has been saved.
5. Replace the PROTeCT link on the NessPD to write-protect the saved data.
6. The panel should be in normal operating mode (or powered off).
7. Connect the NessPD to the ReADeR header on the panel.
8. Use the keypad to enter installation Program mode (or power up the panel with box tamper
unsealed). At this stage, all panel programming options will be automatically copied from the
NessPD to the panel. The green leD on the NessPD will turn on for 2sec to indicate the data
has been copied.
9. exit installation Program mode.
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl

HoW to enter ProgrAm moDe

MeTHOD 1. FIRST TIMe PROGRAMMING – FROM POWeR UP
1. Power-up with the PROG/TAMP link OFF.
Replace the PROG/TAMP link (or Box Tamper lead) after
programming. The link must be on in normal operating mode.
MeTHOD 2. USING THe KeyPAD TO eNTeR PROGRAM MODe
The panel must be Disarmed.
[MASTER CODE]
1. Press
This is User Program Mode (PROGRAM light is ON).
[INSTALLER CODE]
2. Press
This is Installer Program Mode (PROGRAM light is FlASHING).
HoW to exit ProgrAm moDe
1. Press
then
exits directly to Operating Mode (PROGRAM light is OFF).
Power up with Program Link OFF
INSTALLER PROGRAM Mode
(Usually on first time installation)
P r o g r A m m i n g
the keypad will respond with 3 beeps
the keypad will respond with 3 beeps
PROGRAM LIGHT IS FLASHING
PROG
+
+
[INSTALLER CODE]
Factory default Installer Code: 000000
USER PROGRAM Mode
PROG
PROGRAM LIGHT IS ON
+
+
[MASTER CODE]
Factory default Master Code: 123
OPERATING Mode