P r o g r A m m i n g

Zone To Output Mapping

applies to zones when the panel is
in the Armed or 24hr state.
For Home and DAy mode Output
Mapping – see Option P63e
1e–8e, page 28.
P54e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All ON: All zones trigger Reset output.
notes
• 0e will turn all selections OFF.
MeMory e will turn all selections ON.
P55e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
all ON: All zones trigger Strobe output.
notes
• 0e will turn all selections OFF.
MeMory e will turn all selections ON.
P56e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
All ON: All zones sound the Keypad
Sonalert.
notes
• 0e will turn all selections OFF.
MeMory e will turn all selections ON.
22
Zone to oUtPUt mAPPing
When a zone alarms, it can turn on any or all of the following 6 outputs: Sonalert,
Strobe, Siren, Reset, AUX1, AUX2.
The programming is selected with options P54e – P59e. Simply set the zone number
to the output to select it. The zone leD will indicate if the zone is selected.
The Tamper Input and the Keypad Panic can be programmed to turn on the Reset,
Strobe, Sonalert and Siren by using option P61e.
mAPPing Zones to oUtPUts
Option No.
Description
P54e
ReSeT Zones
P55e
STROBe Zones
P56e
SONAleRT Zones
P57e
SIReN Zones
P58e
AUX1,3 Zones
P59e
AUX2,4 Zones
reset oUtPUt Zones
Selects the zones to trigger the Reset output.
PROGRAMMING SeQUeNCe:
P54e [Zone no]e toggles the options ON and OFF
[Zone no] oFF: the zone will not trigger the reset output
[Zone no] on: the zone will trigger the reset output
strobe oUtPUt Zones
Selects the zones to trigger the Strobe output.
PROGRAMMING SeQUeNCe:
P55e [Zone no]e toggles the options ON and OFF
[Zone no] oFF: the zone will not trigger the Strobe output
[Zone no] on: the zone will trigger the Strobe output
keyPAD sonAlert Zones
Selects the zones which will sound the Keypad Sonalert (beeper).
PROGRAMMING SeQUeNCe:
P56e [Zone no]e toggles the options ON and OFF
[Zone no] oFF: the zone will not trigger the Keypad Sonalert
[Zone no] on: the zone will trigger the Keypad Sonalert
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
ZONeS 1–8 (D8 & D16)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
ZONeS 9–16 (D16)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D16xd

Table of Contents