Miscellaneous Options - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P64e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Brief Home Alarm disabled.
relAteD oPtions
P51e Set Home zones.
P63e 1e–4e Home Mode output
mapping
P64e 2e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Brief Day Alarm disabled.
relAteD oPtions
P53e Assign Day zones.
P63e 5e–8e Day Mode output
mapping.
P64e 3e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Home zones all have entry Delay2.
relAteD oPtions
P27e entry Delay Time 2.
P51e Assign Home zones.
P63e 1e–4e Home Mode output
mapping.
P64e 4e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: No siren chirps.
relAteD oPtions
P68e 8e Quiet Chirps.
P69e 5e Home Arm by Radio Key.
P120e 2e Home Arm chirps.
P120e 3e Radio Key AUX button arms
Home Mode.
Option No.
P64e
brieF Home moDe AlArm
Alarms in Home Mode can either activate the programmed outputs for Siren Time
duration (P29e) or they can activate the outputs for 2 seconds only.
NOTe: If Brief Home alarm is enabled, then Home alarms will not be reported by dialler.
PROGRAMMING SeQUeNCe:
P64e 1e toggles the option ON and OFF
oFF: Home Mode outputs have normal time as set by P29e
on: Home Mode outputs are on for 2 seconds only
brieF DAy AlArm
Alarms in Day Mode will activate the programmed outputs while the zone is unsealed
or they can activate the outputs for 2 seconds only.
this option also enables the temPorAry DAy Zone feature. see page 20.
PROGRAMMING SeQUeNCe:
P64e 2e toggles the option ON and OFF
oFF: Brief Day alarm disabled. Day alarm outputs are on while the zone is unsealed
on: Brief Day alarm enabled. Day alarm outputs are on for 2 seconds only
Home Zones entry DelAy 2
Home zones can either have the delay types set by options P40e–P43e or they can all
be assigned to have entry Delay 2. This allows all Home zones to be programmed with
the same entry delay time.
PROGRAMMING SeQUeNCe:
P64e 3e toggles the option ON and OFF
oFF: Home zones behave as programmed by P40e–P43e
on: Home zones all have entry Delay 2
Arm/DisArm CHirPs
If this option is selected the Siren output will "Chirp" when the panel is armed and
disarmed with the Keyswitch input, prox cards or Radio Keys. This option applies to
siren chirps, the strobe output always flashes when arming/disarming by the above
methods. (Home arming chirps are enabled separately by option P120e 2e).
The siren output will make 1 Chirp on Arming, and 3 Chirps on Disarming.
PROGRAMMING SeQUeNCe:
P64e 4e toggles the option ON and OFF
oFF: no arm/Disarm siren chirps
on: Siren & Strobe outputs will chirp on arm/disarm
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Description
1e
Brief Home Alarm
2e
Brief Day Alarm
3e
Home zones entry Delay2
4e
Radio Key SIReN CHIRPS
5e
[not used]
6e
Strobe Flash on Home arm by radio
7e
[not used]
8e
[not used]
P r o g r A m m i n g
Default
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
29