Various Options; Keyswitch Operation - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P r o g r A m m i n g
P60e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
entry Beeps ON.
relAteD oPtions
P69e 7e Arm exit Beeps.
P69e 8e Home exit Beeps.
P60e 2e, 3e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
No keyswitch enabled.
P60e 2e, 3e off.
notes
The keyswitch:
a/ Always Arms Area1 only.
b/ Does not arm Area2.
c/ Can disarm Area2 if option P120e 8e is
enabled.
• The keyswitch input will only operate if
the eOl resistor value of 2k2 is selected
for zone inputs. See P129e, page 68.
relAteD oPtions
P120e 1e latched Keyswitch.
P120e 4e Keyswitch Disarms only.
P120e 5e Keyswitch Arms only.
P120e 8e Keyswitch disarm Area2.
P129e eOl Resistor value
24
Option No.
P60e
1e
2e
3e
4e
5e
6e
7e
8e
entry beePs
The sonalert will beep during entry Delay.
PROGRAMMING SeQUeNCe:
P60e 1e toggles the option ON and OFF
oFF: entry Beeps oFF
on: entry Beeps on

keysWitCH oPerAtion

An externally fitted, normally open momentary Keyswitch can be used to Arm, Disarm
or arm the Home mode.
The keyswitch is wired to zone 8 (zone 8 is then no longer available as a normal alarm
input, but is still available for use as a Radio Zone).
PROGRAMMING SeQUeNCe:
P60e 2e or 3e toggles the option ON and OFF
2e & 3e oFF: no keyswitch operation. Zone 8 is a normal alarm input.
2e on: Keyswitch cycles between Home and Disarm.
3e on: Keyswitch cycles between arm and Disarm.
2e & 3e on: Keyswitch cycles between arm, Home and Disarm.
MONITOR
DISARM
Momentary
Keyswitch
P60e 2e is on
KeySWITCH WIRING
If P60e 2e or 3e are enabled, use a momentary action keyswitch with normally open
contacts. A momentary closed circuit across the resistor will toggle panels modes.
Open circuit the resistor to trigger Panic if required. (Panic on this input is disabled if
P120e 1e is enabled).
If P120e 1e is enabled, use a latching keyswitch. When the resistor is sealed, panel is
disarmed. If the resistor is unsealed, (either by open circuit or short circuit), the panel
will arm Area1, (Area2 will be ignored).
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Description
entry Beeps
Keyswitch Home Monitor/Disarm
Keyswitch Arm/Disarm
Tamper Siren lockout
Duress to ReSeT output
Auto exclude zones
Auto keypad display off
Delayed Aux3, Aux4 outputs
ARMED
MONITOR
DISARM
Momentary
Keyswitch
P60e 3e is on
ARMED
MONITOR
ARMED
DISARM
DISARM
DISARM
Momentary
latching
Keyswitch
Keyswitch
P60e 2e is on
P120e 1e is on
P60e 3e is on
KeySWITCH WIRING.
A momentary or latching keyswitch
can be wired as shown.
Default
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ARMED
MONITOR