Dialling Options - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P87e 1e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF: Split Dial.
relAteD oPtions
P87e 4e Number of Dialling attempts.
P87e 2e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: Dial only with dial tone.
P87e 4e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
ON: 4 dialling attempts.
notes
• Sets the total number of dialling
attempts. e.g. If 4 dialling attempts is
selected, this means 2 attempts per
telephone number.
relAteD oPtions
P87e 1e Alternate dialling.
P87e 5e, 6e, 7e
Available in D8x/D16x V8 and later.
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
OFF
Option No.
P87e
1e
2e
3e
4e
5e
6e
7e
sPlit DiAl PrimAry/seConDAry PHone nUmbers
This option selects the order in which Telephone numbers 1 & 2 are dialled.
PROGRAMMING SeQUeNCe:
P87e 1e toggles the option ON and OFF
oFF: Split Dial. Dial telephone no.1 for half of the call attempts. if unsuccessful, dial telephone
no.2 for the last half of call attempts.
on: Alternate Dial. Dial telephone no.1 on the first attempt. if no answer, dial telephone no.2.
Continue alternating until successful.
CHeCk For DiAl tone
The dialler can be programmed to check for a dial tone before dialling. The dialler will
still dial out if a dial tone is not detected , but this means several seconds will have
elapsed. Allows use on PABXs with non-standard dial tones.
PROGRAMMING SeQUeNCe:
P87e 2e toggles the option ON and OFF
oFF: Dial without dial tone
on: Dial only with dial tone
nUmber oF DiAlling AttemPts
Sets the number of dialling attempts when sending reports.
OFF: sets a maximum 10 dial attempts before a 5 minute sleep and 10 more re-tries if
unsuccessful.
ON: allows a maximum of 4 dial attempts before a 5 minute sleep and 4 more retries if
unsuccessful.
If all attempts fail the dialler waits for the next trigger event. The previously
unsuccessful report will be included in the new message.
When sending Test Calls, the time between dialling attempts increases to 60 minutes
for the second round of dialling. If a Test Call is unsuccessful after the first round of
calls are made, another call is made after 5 minutes. If this call fails then subsequent
calls are made every hour (up to the maximum number of calls).
PROGRAMMING SeQUeNCe:
P87e 4e toggles the option ON and OFF
oFF: Maximum 10 dialling attempts
on: Maximum 4 dialling attempts
Pstn - reDUCe tone leVels
This option allows PSTN tone levels to be reduced which may be required when the
panel is using VOIP type phone lines.
PROGRAMMING SeQUeNCe:
P87e 5e, 6e or 7e toggles the option ON and OFF
5e: reduce tone output when dialling telephone number
6e: reduce tone output when sending alarm message
7e: reduce tone output when connecting to modem
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Description
Split dial Primary/Secondary numbers
Check for Dial Tone
[not used]
4 Dialling attempts
Reduce tone output when dialling telephone number
Reduce tone output when sending alarm message
Reduce tone output when connecting to modem
P r o g r A m m i n g
Default
OFF
ON
OFF
ON
OFF
OFF
OFF
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D16xd

Table of Contents