Clear Radio Devices; Clear Memory; Clear Panel Options; Clear User Codes - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

These options allow selective restoring
of various factory defaults. For example,
you can default (clear) all the User
Codes, without affecting any other
programmed options.
P95e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
[not applicable]
P96e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
[not applicable]
P97e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
[not applicable]
notes
Note, this option will also delete Radio
Devices programmed on zones.
P98e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
User Code 1: 123
All other codes: [blank]
notes
• This option DOES NOT clear the
Installer Code.
P99e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
000000
Option No.
P95e
P96e
P97e
P98e
P99e

CleAr rADio DeViCes

This option clears all Radio Devices assigned to zones 1–8 or 1–16.
(This option does not clear User Codes).
PROGRAMMING SeQUeNCe:
P95e Clears Radio Device Codes

CleAr memory

enter P96e when in Installer Program mode to clear all events in the Alarm memory
display.
Note: This option clears only the 20 event memory as read by KPX and lCD keypads.
Ness Navigator touch screen keypad's 80 event memory is not affected.
PROGRAMMING SeQUeNCe:
P96e Clears Alarm Memory display

CleAr PAnel oPtions

This option restores 'panel' program options to their factory default values.
Defaults all program options except User Codes and Radio Codes.
note, this option will also delete radio Devices programmed on zones.
PROGRAMMING SeQUeNCe:
P97e Restores Factory Defaults

CleAr User CoDes

This option clears all User Codes, (this means all Keypad Codes, Radio Keys and
Access cards) and restores User Code 1 to the factory setting of 123.
P201e – P256e are defaulted (User Codes 1–56)
PROGRAMMING SeQUeNCe:
P98e Clears User Codes
ProgrAm tHe instAller CoDe
Programs the installer code. This code can be 3 to 6 digits long. Factory default
installer code is 000000.
PROGRAMMING SeQUeNCe:
P99e [enter new code]e [enter new code again]e
(Unlike User Codes, the installer code is not displayed when programming)
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Description
CleAR RADIO DeVICeS
CleAR MeMORy
CleAR PANel OPTIONS (ReSTORe FACTORy DeFAUlTS)
CleAR USeR CODeS

PROGRAM INSTAlleR CODe

For a complete list of factory default values, see the
Programming Options Summary on pages 86–91.
P r o g r A m m i n g
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D16xd

Table of Contents