Aux3 Output Options - Ness D8xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

P r o g r A m m i n g
Only one of the P123e options may be selected.
Option No.
Description
P123e 1e
Zone Alarms to AUX3
2e
[not used]
3e
enable AUX3 for AutoTimer
4e
Radio Key Panic Pulses AUX3
5e
[not used]
6e
[not used]
7e
[not used]
8e
Reader output pulses Aux3
P123e 1e
Available in D8x/D16x V8 and later.
relAteD oPtions
P58e Aux1,3 zones.
P121e 1e Zone Alarms to AUX1
P123e 1e-8e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
1e on.
notes
Only one option can be on. Turning an
option on turns off another.
relAteD oPtions
P143e 1e-8e enhanced AUX3 options.
P374e 5e-6e AutoTimer1 AUX3 options.
P379e 5e-6e AutoTimer2 AUX3 options.
P384e 5e-6e AutoTimer3 AUX3 options.
P389e 5e-6e AutoTimer4 AUX3 options.
P123e 3e
Available in D8x/D16x V8 and later.
relAteD oPtions
P370e to P389e. AutoTimers.
P123e 4e
Available in D8x/D16x V8 and later.
notes
When this option is on, Radio Key Panic
buttons will no longer sound alarms or
report alarms by dialler.
relAteD oPtions
P147e AUX3 Timer
P123e 8e
relAteD oPtions
P318e, P328e, P338e, P319e, P329e,
P339e.
62

AUx3 OUTPUT OPTIONS

Default
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Zone AlArms to AUx3
With this option ON, zones selected in P58e will turn on Aux3 when they go into alarm. The
Aux3 output turns off when the panel is disarmed/reset.
AUx3 oUtPUt oPtions
P123e is one of several options which control the behaviour of the AUX3 output.
One of the most powerful features of the D8x/D16x panels is the flexibility to control
the AUX outputs by various events and alarms. If the AUX3 output does not behave as
expected, please check all related options such as AutoTimers and P143e options.
TO PROGRAM
1. Press P123e.
2. Press 1e ... 8e to turn an option on. Only one option can be on.
enAble AUx3 For AUtotimer
When this option is on, AUX3 is enabled for use by AutoTimer.
rADio key PAniC PUlses AUx3
When this option is on, Radio Key/s Panic button will PUlSe the Aux3 output.
Note that P121e 4e (Radio Key Panic Pulses AUX1) over-rides this option.
reADer oUtPUt to AUx3
This option enables an access control reader to pulse Aux3 when a valid access card is
presented. Set the reader using P318e, P328e or P338e.
NeSS D8X / D16X DelUXe CONTROl PANel – INSTAllATION MANUAl
Any or all of the P143e options may be selected.
Option No.
Description
P143e 1e
Area1 Armed to AUX3
2e
Area2 Armed to AUX3
3e
Home Mode arm to AUX3
4e
Keypad toggle AUX3
5e
Telephone remote control of AUX3
6e
[not used]
7e
[not used]
8e
Pulse AUX3
Default
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF

Hide quick links: