P65e
ProgrAm moDe leVel
Installer mode or NessComms.
FACtory DeFAUlt
all OFF: No Supervision zones.
relAteD oPtions
P66e 1e–4e Supervision Alerts.
P66e 5e Wired Zone Supervision.
P67e Zone Supervision Time.
P92e 4e (D8) Report Supervision.
P75e 12e (D16) Report Supervision.
notes
0e will turn all selections OFF.
MeMory e will turn all selections ON.
If Radio Supervision is enabled, P66e
5e off, then the supervision feature
cannot be used as an inactivity monitor.
Option No.
Description
P65e
SUPeRVISeD ZONeS
sUPerViseD Zones
Any zone 1-8 or 1-16 can be a Supervised Zone.
supervision for HArDWireD Zones
In operation, a Supervised Zone is subject to the Supervision Time (P67e). If the zone/s
has not sealed or unsealed during the Supervision Time, then the programmed alerts
will turn on (as programmed by P66e 1e-4e, P92e 4e or P75e 12e). Zone Supervision
can be used as an "inactivity monitor" to sound an alert or send a dialler report if a
zone has had no activity during a set period of time. (For example, to monitor an aged
person's home).
• A zone which is permanently in a sealed or unsealed state for the duration of
Supervision Time will be treated as a Supervision alarm.
• If P66E 5E is on, Zone Supervision acts on wired zones. If P66E 5E is off, Zone
Supervision acts on radio zones.
• Each Supervised zone has its own supervision timer.
• Zone Supervision is independent of the armed state of the panel.
• Zone Supervision can be temporarily disabled by Excluding the zone/s.
• The zone which caused the Supervision alarm flashes on the keypad. Entering a
valid code + e will reset Supervision alarms.
supervision for rADio Zones
The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs.
The Supervision signal from the Radio PIR tells the panel that the device has not been
removed from radio range and is in working order.
A non-SUPeRVISION enabled Radio PIR will transmit signals to the panel only when it
has detected an event. Obviously, there is no guaranteed signal period.
In either case, when the allowed time limit is exceeded then a WARNING is first
given (if programmed by P66e 3e), and then after 1 minute, the programmed RADIO
SUPeRVISION AleRTS are generated by the panel.
P66e 5e must be off for supervision to work on radio zones.
PROGRAMMING SeQUeNCe:
P65e [Zone no]e toggles the options ON and OFF
[Zone no]e oFF: the zone is not a Supervised Zone
[Zone no]e on: the zone is a Supervised Zone