3.Printer-specific Adjustments
3.1.1

Gamma Balance Adjustment

In order to make the low/middle density areas darker in black-and-white printing, set a larger value for
the subcode 0 or 1.
PDL/
Halftone
Resolution
Smooth
Detail
PS
600 dpi
Auto
Smooth
Detail
PS
1200 dpi
Auto
Smooth
Detail
PCL
600 dpi
Auto
Smooth
Detail
XPS
600 dpi
Auto
Subcode
Density area to be adjusted
0
Low density
1
Middle density
2
High density
• Set the value in increments of around 10, while checking the print image until the optimum value is
obtained.
• Adjust PS for Mac.
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
Object
[05] Code Subcode
Text, Graphic &
05-7315
Image
Text, Graphic &
05-7316
Image
Text
05-7360
Graphic
05-7361
Image
05-7362
Text, Graphic &
05-7309
Image
Text, Graphic &
05-7310
Image
Text
05-7357
Graphic
05-7358
Image
05-7359
Text, Graphic &
05-7317
Image
Text, Graphic &
05-7318
Image
Text
05-7363
Graphic
05-7364
Image
05-7365
Text, Graphic &
05-7319
Image
Text, Graphic &
05-7320
Image
Text
05-7366
Graphic
05-7367
Image
05-7368
3-2
Recommended
value
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
Set a value
0/1/2
larger than
128.
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2
0/1/2