3.5.4 Gamma balance adjustment

The density adjustment at the Black Mode is performed by selecting its density area from the
following: low density, medium density and high density.
Color
Original mode
mode
Text/Photo
590-0
Black
590-1
590-2
Make a test copy and compare the image obtained with the current settings; if necessary, make
adjustment using the following procedure.
Note:
Be sure that this adjustment be made after performing "3.5.1 Automatic gamma adjustment".
<Procedure>
Procedure is same as that of "3.5.3 Color balance adjustment".
November 2003 © TOSHIBA TEC
Photo
Text
591-0
592-0
591-1
592-1
Medium density
591-2
592-2
3 - 25
Item to be
adjusted
The larger the value is, the density
Low density
of the item to be adjusted becomes
darker.
Acceptable values: 0 to 255.
(Default: 128)
High density
e-STUDIO3511/4511 ADJUSTMENT
<Adjustment Mode (05)>