C a l l i n g T e c h n i c a l S u p p o r t
Technical support representatives are available Monday through Friday during regular business
hours. Follow these steps before calling:
1. Make sure the PC and printer are properly connected.
2. Record any error messages that occurred.
3. Recreate the problem, if possible.
4. Check the communication port settings and change if necessary.
5. List any recent changes to the system. Record what you were doing when the problem
occurred.
6. Reset the printer, see "Resetting the Printer."
7. Reboot the computer. Refer to the computer documentation for specific instructions.
8. Print a test label, see "Printing a Test Label" for more information.
Have the following information ready before calling: computer brand name and model, printer
model, other peripheral devices on your system, support agreement, contract number, or invoice
information, customer number, and printer serial number.

Data Errors

Call Technical Support if any error message is received that is not listed below.
Errors 001 to 499 are data errors. These errors are returned in response to a J,3 request. See
Chapter 7, "Status Polling," for more information. A data error indicates that incorrect data was
received from the host, causing the printer to ignore the entire print job. After checking the
packet and correcting the problem, transmit the print job again.
The following is a list of data errors. These errors occur because data in the format, batch,
check digit, font, or graphic packet is invalid.

Format Errors

Error
Description
Code
001
Packet ID number must be 1 to 999.
002
Name must be 1 to 8 characters (excluding non-printable control characters) inside
quotes. The range is 1 to 256 characters for the XML-enabled printer.
003
Action must be A (add) or C (clear).
004
Print length is invalid. See
005
Print width is invalid. See
006
Storage device must be F (Flash), R (volatile RAM), or T (temporary for graphics).
007
Unit of measure must be E (English), M (Metric), or G (Dots). See
Header" in Chapter 3 for more information.
010
Field ID number is outside the range 0 to 999.
011
Field length exceeds 2710.
012
Row field position is greater than the maximum stock dimension. See "Defining Text