Error
Description
Code
793
The printer job queue is full. Turn off the printer. Wait 15 seconds and turn it back on.
Resend the packets. If the problem continues, call Technical Support.
794
The backfeed mode is not set.
795
Print engine lock-up. Call Technical Support.
796
No job quantity for the job setup. If this error message appears, call Technical Support.
797
No sub-job quantity for the job setup. If this error message appears, call Technical
Support.
799
Job quantity mismatch. If this error message appears, call Technical Support.
F l a s h M e m o r y E r r o r s
Error
Description
Code
800
A directory in flash memory is full.
801
Flash memory is full.
802
A directory in flash memory can't be found.
803
There is no directory in flash memory.
810
A file in flash memory is not open.
811
A file in flash memory is already open.
812
The file in flash memory is full.
813
Flash memory is not accessible.
820
An error occurred in the flash program.
821
An error occurred while erasing flash memory.
822
Flash ID error.
S c r i p t E r r o r s
These errors occur when there is a script (application) problem.
Error
Description
Code
850
Invalid script packet or not enough flash memory for the script. The script download
failed. Format flash memory and download the script using the Command prompt.
851
Invalid lookup table or not enough flash memory for the script. The lookup table
download failed. Check the data in the lookup table. Format flash memory and
download the script using the Command prompt.
852
Invalid buffer definition packet or not enough flash memory for the script. Invalid input
buffer, temporary buffer, lookup buffer, printer, or array buffer. Check the buffer
definitions. Format flash memory and download the script using the Command prompt.
853
Invalid version string or not enough flash memory for the script. The version information
in the APPVERSION command is missing or invalid. Make sure the information is
enclosed in double quotation marks. Format flash memory and download the script using
the Command prompt.
854
Invalid table (string and numeric) data or not enough flash memory for the script. Check
the data. Format flash memory and download the script using the Command prompt.
855
Invalid start/clear command. The script is missing the start or clear command {S space}.