Avery Dennison ADTP1 Reference Manual page 131

Monarch tabletop printer 1
Hide thumbs Also See for ADTP1:
Table of Contents

Advertisement

The following syntax is the response for a Job 3 request. Press FEED (if necessary) to return the
job response.
Syntax
{J,"Status1 A,B","Status2
A,B,C,D,E","FMT-1","BCH-2"}
J1. J
J2. "Status1 A,B"
J3. "Status2 A,B,C,D,E"
J4. "FMT-1"
J5. "BCH-2"
Example {J,"2,612",}
2 is the field number where an error was found. 612 is the error number, indicating that data is
missing or does not match the format definition for that field.
Note:
If more than one error occurred, only the most serious error is acknowledged.
Example
{J,"","F,B,4,6,33","FMT-1","BCH-2"}
Indicates that an error occurred on a bar code (B) field within a format (F) packet. The bar code
field is the fourth (4) field in the packet. The error occurred in the sixth (6) parameter of the field.
Error number 33 means the bar code density is invalid.
To clear an error, press ESCAPE/CLEAR. An ENQ can also clear errors numbered less than
500. Once the error is corrected, a job request can be sent. The printer cannot accept another
job request until the error is resolved.
The following syntax is the response for a Job 4 request.
Syntax
{J,printed,total,"FMT-1","BCH-2"}
Printed
Total
"FMT-1/BCH-2"
Example {J,8,25,"FMT-3","Bch-2"}
8 out of 25 tags or labels are left to print from format number 3.
Job Response Identifier.
Status 1A contains the field number, in the format or batch, where
an error was found. If the error is not in the format or batch, a "0" is
returned.
Status1 B contains the error number. See Chapter 8, "Diagnostics
and Errors."
Status2 A contains the packet type, field type, field number,
parameter, and error number:
A
The MPCLII packet that has an error - Format (F), Batch (B),
Check Digit (A), Graphic (G), or Font (W).
B
The MPCLII field that has an error. If the packet has no fields,
Status2 A is replicated. If the error occurs before the field is
identified a question mark is sent. Since the batch data is
variable, a D is sent to indicate data.
C
The field number within each packet. The packet header is the
first field and each subsequent field is indicated by the field
separator.
D
The parameter within the field that has an error. The
numbering begins after the field identifier.
E
The error number. See Chapter 8, "Diagnostics and Errors."
Returns the format number.
Returns the batch number.
the number of tags or labels remaining in the batch to print.
the total number of tags or labels to be printed in the current
batch.
The format or batch number is returned.
Status Polling 7-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents