DMA Operations Guide
Configure Logging
54
To set up H.323 access via a gatekeeper:
5
Select Register to gatekeeper.
a
Enter the IP address or host name for the primary gatekeeper.
b
Enter the IP address or host name for the secondary gatekeeper
c
(optional).
If registering with a Cisco Multimedia Conference Manager (MCM),
d
Tandberg Video Communications Server (VCS), or other
non-Polycom gatekeeper, set Gatekeeper type to Other.
To make the system accessible via SIP calls:
6
Select Enable SIP signaling.
a
If the system's security settings permit unencrypted SIP connections,
b
optionally select TCP or UDP/TCP from the list.
You must have the Administrator role to change security settings. See
"Security Configuration"
Leave the default port numbers (5060 for TCP/UDP, 5061 for TLS)
c
unless you have a good reason for changing them.
Note
The system only answers UDP calls if that transport is enabled. But for
communications back to the endpoint (assuming unencrypted connections are
permitted), it uses the transport protocol that the endpoint requested.
For more information about this and other aspects of SIP, see
Click Update.
7
A dialog box informs you that the configuration has been updated.
Click OK.
8
The system processes the configuration and attempts to register with the
gatekeeper. The H.323 signaling status and Status fields show the current
state.
See also:
"Signaling Configuration"
To configure logging
Go to Configuration > System > Logging Configuration.
1
Change Rolling frequency and Retention period as desired.
2
If requested to do so by Polycom support, change Logging level.
3
System Configuration Procedures
on page 32.
on page 45
RFC
3261.
Polycom, Inc.
Need help?