Mazda B-Series 1997 Workshop Manual page 585

Table of Contents

Advertisement

TROUBLESHOOTING GUI I E , CHARGING SYSTEM
1
3
1
Cranks slowly
I
STEP
INSPECTION
Does engine crank normally with fully charged
battery?
Yes
No
ACTION
Check charging system
*
page G-12
Go to next step
Are starter cable connections loose or corroded?
Yes
Repair connection
I I
Check starter for binding (brush,
armature, etc.)
a s
page G-61
Inspect ring gear and service
as required
*
page G-62
Generator warning light illuminates while engine running
I
STEP
INSPECTION
Is battery positive voltage correct at idle?
Specification 14.1-1 4.7V
terminal and generator warning light
as
page G-12
1
5
1
Discharged battery
I
STEP
- - -
1
INSPECTION
Is charging system OK?
u s
page G-12
ACTION
I
Yes
Turn ignition switch ON and mt, lasure
dark current as shown
Dark current: Below 0.05A
If the dark current exceeds 0.05A, check for constant
current drain such as a vehicle lamp. If not visibly
noticeable, pull the fuses one at a time until the
cause of the drain is located.
Repair or replace regulator or generator
I