Scsi Fixed Disk Drive Test Error Codes; Scsi/Ide Cd-Rom Drive Test Error Codes - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

SCSI Fixed Disk Drive Test Error Codes

The 6500 series of Diagnostic error codes identifies failures with SCSI fixed disk drives, SCSI
fixed disk drive controller boards, SCSI fixed disk drive cabling, and system board functions.
Corrective action may require replacement of fixed disk drive cables, fixed disk drive
controllers, fixed disks, or the system board assembly. If your system uses a drive array
controller, see the section for Drive Array Advanced Diagnostics (DAAD).
Error Code
6500-xx
6502-xx
6505-xx
6506-xx
6509-xx
6523-xx
6528-xx

SCSI/IDE CD-ROM Drive Test Error Codes

The 6600 series of Diagnostic error codes identifies failures with the CD-ROM cabling, CD-
ROM drives, adapter boards, or the system board assembly. Corrective action may require
replacement of the CD-ROM cabling, a CD-ROM drive, an adapter board, or the system
board assembly.
Error Code
6600-xx
6605-xx
SCSI Fixed Disk Drive Test Error Codes
Description
SCSI Disk ID drive types test failed.
SCSI Disk Unconditional Format test
failed.
SCSI Disk Read Test Failed.
SCSI Disk SA/Media test failed.
SCSI Disk Erase tape test failed.
SCSI Disk Random Read test failed.
Media load/unload test failed.
SCSI/IDE CD-ROM Drive Test Error Codes
Description
CD-ROM ID failed.
CD-ROM Read failed.
Table 3-16
Recommended Action
The following steps apply to error codes
6500-xx through 6528-xx:
1. Run the System Configuration Utility and
verify the drive type.
2. Replace the SCSI disk drive signal and
power cables and retest.
3. Replace the SCSI controller and retest.
4. Replace the SCSI disk drive and retest.
5. Replace the system board and retest.
Table 3-17
Recommended Action
The following steps apply to error codes
6600-xx through 6605-xx:
1. Replace the CD-ROM media and retest.
2. Check and/or replace the signal cable
and retest.
3. Check the switch settings on the
adapter board (if applicable).
4. Replace the SCSI controller (if
applicable) and retest.
5. Replace the CD-ROM drive and retest.
6. Replace the system board and retest.
Compaq ProLiant 1600 Servers Maintenance and Service Guide