DAAD Diagnostic Messages
Message
Controller is
Controller is not configured. If
not configured
controller was previously
configured and you change drive
locations, there may be a
problem with placement of the
drives. DAAD examines each
physical drive and looks for
drives that have been moved to
a different drive bay.
Controller
IDA firmware is less than version
needs
0.96.
replacing
(DAAD
Error 102)
Controller
The Intelligent Array Expansion
needs
System firmware is less than
replacing
version 1.14.
(DAAD Error
104)
Controller
The controller returned an error
reported
from its internal Power-On Self
POST error.
Tests.
Error Code: x
Controller
DAAD did not find a valid
restarted with
configuration signature to use to
a signature of
get the data. Nonvolatile RAM
zero
may not be present
(unconfigured) or the signature
present in nonvolatile RAM may
not match the signature on the
controller.
DAAD
DAAD found errors while
recorded
attempting to access physical
errors
drive X, believed to be
attempting to
operational. Message followed
access: X
by specific information about the
error.
Disable
Posted-writes have been
command
disabled by the issuing of the
issued
Accelerator Disable command.
This occurred because of an
operating system device driver.
Continued
Description
Look for messages indicating which drives
have been moved. If none appear and drive
swapping did not occur, run the System
Configuration Utility to configure the controller
and nonvolatile RAM. Do not run the System
Configuration Utility if you believe drive
swapping
has occurred.
Replace the controller as soon as possible.
Replace the controller as soon as possible.
Replace the controller.
Run the System Configuration Utility to
configure the controller and nonvolatile RAM.
Replace the drive, or correct the condition that
caused the error.
Restart the system. Run the System
Configuration Utility to reinitialize the array
accelerator board.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Recommended Action
3-51

Hide quick links:

Advertisement

Table of Contents
loading