POST Error Messages
Audible
Error Code
Beeps
L=Long S=Short
213-System
Processor Not
Installed
214-DC-DC
Converter Failed
301-Keyboard
Error
301-Keyboard
Error or Test
Fixture Installed
ZZ -301-
Keyboard Error
303-Keyboard
Controller Error
304-Keyboard or
System Unit
Error
40X-Parallel Port
X Address
Assignment
Conflict
402-
1L, 2S
Monochrome
Adapter Failure
501-Display
1L, 2S
Adapter Failure
Continued
Probable Source of
Problem
1S
System processor
configured for slot
indicated is missing.
None
PowerSafe Module (DC-
DC Converter) failed.
None
Keyboard failure.
None
Keyboard failure.
None
Keyboard failure. ( ZZ
represents the Keyboard
Scan Code.)
None
System board, keyboard,
or mouse controller failure.
None
Keyboard, keyboard cable,
or system board failure.
2S
Both external and internal
ports are assigned to
parallel port X.
Monochrome display
controller.
Video display controller.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Action
Install processor in the slot
indicated or run the System
Configuration Utility to remove
the processor from the
. CFG file.
Run Diagnostics. Replace failed
assembly as indicated.
Turn off the computer, then
reconnect the keyboard.
Replace the keyboard.
1. A key is stuck. Try to free it.
2. Replace the keyboard.
1. Run Diagnostics.
2. Replace failed assembly as
indicated.
1. Make sure the keyboard is
attached.
2. Run Diagnostics to
determine which is in error.
3. Replace the part indicated.
Run the System Configuration
Utility and correct.
Replace the monochrome
display controller.
Replace the video board.
3-9