Diskette Drive Test Error Codes
The 600 series of Diagnostic error codes identifies failures with diskette, diskette drive, or
system board functions. Corrective action may require replacement of a diskette, a diskette
drive, or the system board assembly.
Error Code
600-xx
601-xx
602-xx
603-xx
604-xx
605-xx
606-xx
607-xx
608-xx
609-xx
610-xx
694-xx
697-xx
698-xx
699-xx
Monochrome Video Board Test Error Codes
The 800 series of Diagnostic error codes identifies failures with monochrome video boards or
system board functions. Corrective action may require replacement of a monochrome video
board or the system board assembly.
Error Code
802-xx
824-xx
Diskette Drive Test Error Codes
Description
Diskette ID drive types test failed.
Diskette format failed.
Diskette read test failed.
Diskette write/read/compute test failed.
Diskette random seek test failed.
Diskette ID media failed.
Diskette speed test failed.
Diskette wrap test failed.
Diskette write protect test failed.
Diskette reset controller test failed.
Diskette change line test failed.
Pin 34 is not cut on 360 KB diskette drive.
Diskette type error.
Diskette drive speed not within limits.
Diskette drive/media ID error.
Monochrome Video Board Test Error Codes
Description
Video memory test failed.
Monochrome video text mode
test failed.
Table 3-7
Recommended Action
The following steps apply to error codes
600-xx through 698-xx:
1. Replace the diskette and retest.
2. Check and/or replace the diskette
power and signal cables and retest.
3. Replace the diskette drive and retest.
4. Replace the system board and retest.
1. Replace the media and retest.
2. Run the Configuration utility and
retest.
Table 3-8
Recommended Action
The following steps apply to error codes 802-xx and 824-
xx:
1. Replace monitor and retest.
2. Replace the Advanced VGA board and retest.
3. Replace monochrome board and retest.
4. Replace the system board and retest.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
3-31