Scsi Tape Drive Test Error Codes; Server Manager/R Board Test Error Codes - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

3-40
Diagnostic Tools

SCSI Tape Drive Test Error Codes

The 6700 series of Diagnostic error codes identifies failures with tape cartridges, tape drives,
media changers, tape drive cabling, adapter boards, or the system board assembly. Corrective
action may require replacement of a tape cartridge, tape drive, media changer, tape drive
cabling, adapter board, or the system board assembly.
Error Code
6700-xx
6706-xx
6709-xx
6728-xx

Server Manager/R Board Test Error Codes

The 7000 series of Diagnostic error codes identifies failures with the Server Manager/R board.
Corrective action may require replacement of the Server Manager/R board, the Integrated
2400-baud modem, voice ROM, or the battery on the Server Manager/R board.
Error Code
7000-11
7000-12
7000-13
7000-14
7000-15
7000-21
7000-22
7000-23
7000-24
SCSI Tape Drive Test Error Codes
Description
SCSI Tape ID drive types test failed.
SCSI Disk SA/Media test failed.
SCSI Disk Erase tape test failed.
Media load/unload test failed.
Server Manager/R Board Test Error Codes
Description
Processor (80186 Timer).
Processor (80186 Registers).
Processor (Watch Dog Timer).
Processor (8570 RAM).
Processor (8570 RTC).
Memory.
Memory Write/Read.
Memory Address.
Memory Refresh Alert.
Table 3-18
The following steps apply to error codes
6700-xx through 6728-xx:
1. Run the System Configuration Utility
and verify the drive type.
2. Replace the SCSI Tape drive signal
and power cables and retest.
3. Replace the SCSI controller and
retest.
4. Replace the SCSI Tape drive and
retest.
5. Replace the system board and retest.
Table 3-19
For error codes 7000-11 through
7000-46, replace the Server Manager/R
board and retest.
Recommended Action
Recommended Action
Continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents