POST Error Messages
Audible
Error Code
Beeps
L=Long
S=Short
1790-Disk 0
Configuration
Error
1791-Disk 1
Error
1792-Drive Array
Reports Valid
Data Found in
Array
Accelerator.
Data will
automatically be
written to drive
array.
1793-Drive Array
- Array
Accelerator
Battery Depleted
- Data Lost
(Error message
1794 also
displays.)
1794-Drive Array
- Array
Accelerator
Battery Charge
Low. Array
Accelerator is
temporarily
disabled. Array
Accelerator will
be re-enabled
when battery
reaches full
charge.
Continued
Probable Source of
Problem
None
Hard drive error or wrong
drive type
None
Hard drive error or wrong
drive type.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory. Power was then
restored within eight to ten
days, and the data in the
Array Accelerator was
flushed to the drive array.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory. Array
Accelerator batteries
failed. Data in Array
Accelerator has been lost.
None
This is a warning that the
battery charge is below
75%. Posted-writes are
disabled.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Action
Run the System Configuration
Utility and Diagnostics and
correct.
Run the System Configuration
Utility and Diagnostics and
correct.
No action necessary; no data
has been lost. Perform orderly
system shutdowns to avoid data
remaining in the Array
Accelerator.
Power was not restored within
eight to ten days. Perform
orderly system shutdowns to
avoid data remaining in the
Array Accelerator.
Replace the Array Accelerator
board if batteries do not
recharge within 36 power-on
hours.
Continued