Serial Test Error Codes; Modem Communications Test Error Codes - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

3-32
Diagnostic Tools

Serial Test Error Codes

The 1100 series of Diagnostic error codes identifies failures with serial/parallel interface board
or system board functions. Corrective action may require replacement of the serial/parallel
interface board or the system board assembly.
Error Code
1101-xx
1109-xx

Modem Communications Test Error Codes

The 1200 series of Diagnostic error codes identifies failures with the modem(s). Corrective
action may require replacement of the modem(s).
Error Code
1201-xx
1202-xx
1203-xx
1204-xx
1206-xx
1210-xx
Serial Test Error Codes
Description
Serial port test failed.
Clock register test failed.
Modem Communications Test Error Codes
Description
Modem internal loopback test failed.
Modem time-out test failed.
Modem external termination test failed.
Modem auto originate test failed.
Dial multi-frequency tone test failed.
Modem direct connect test failed.
Table 3-9
The following steps apply to error codes
1101-xx and 1109-xx:
1. Check the switch settings on the
Serial/Parallel Interface board (if
applicable) and retest.
2. Replace the Serial/Parallel Interface
board (if applicable) and retest.
3. Replace the system board and retest.
Table 3-10
The following steps apply to error codes
1201-xx through 1210-xx:
1. Refer to the modem documentation
for correct setup procedures and
retest.
2. Check the modem line and retest.
3. Replace the modem and retest.
Recommended Action
Recommended Action

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents