Compaq ProLiant 1600 Maintenance And Service Manual page 58

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

POST Error Messages
Audible
Error Code
Beeps
L=Long
S=Short
1615- Power
Supply Failure in
Bay X
1616- Power
2L, 2S
Supply
Configuration
Error
1701-SCSI
Controller failure
1702-SCSI cable
error detected.
System halted.
1703-SCSI cable
error detected.
Internal SCSI
cable not
attached to
system board
connector.
System halted.
1704-
Unsupported
Virtual Mode
Disk Operation.
DOS Driver
Required.
System halted.
Continued
Probable Source of
Problem
None
A power supply has failed.
Single power supply
system is installed in Bay
2 and not in Bay 1.
None
A test on the Fast SCSI-2
Controller failed
None
Incorrect cabling.
None
Incorrect cabling.
None
System attempted to
perform a virtual mode
disk operation without
virtual mode memory
services.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Action
Replace or check specified power
supply.
Move power supply from Bay 2 to
Bay 1.
Run Diagnostics. Replace failed
assembly as indicated.
1. For integrated SCSI Controllers,
ensure that the internal
connector has SCSI termination
attached.
2. For option card SCSI
controllers, ensure that only one
of the two internal connectors
has termination attached.
Ensure that the integrated SCSI
controller has SCSI termination
attached.
Use fixed-disk device driver that
supports virtual mode memory
services.
3-13
Continued

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents