Compaq ProLiant 1600 Maintenance And Service Manual page 114

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

The following ASR-2 flow chart shows you the sequence of events after a hardware or
software error occurs:
Unattended server boots the
Operating System
If the server continues experiencing
hardware/software errors and the
number of ASR cycles exceed the
specified number of recovery
attempts, the server will log an error
to the Server Health Log or the
Integrated Management Log and
boot the Compaq Utilities from the
system partition on the hard drive
Figure 3-1. ASR-2 flow chart
Hardware/Software error occurs
Error records in the Critical Error Log,
or the Integrated Management Log,
depending on your server
configuration.
Operating System halts normal
operation
ASR Timer expires
Server is reset
If a modem is installed and paging
is enabled, the Server Failure
Notification pager alert is sent to
the Server Administrator
|
---Or---
Compaq ProLiant 1600 Servers Maintenance and Service Guide
|
|
|
|
|
Server boots the Compaq Utilities
on the system partition on the
hard drive
|
If a modem is installed, ASR puts
the modem on auto answer so that
the Server Administrator can dial in
using third party terminal emulator
software to remotely run the
Compaq Utilities to identify the
source of the fault
|
Or
|
Local Server Administrator runs
Compaq Utilities from server
console to identify the source of
the fault
3-69

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents