Compaq ProLiant 1600 Maintenance And Service Manual page 59

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

3-14
Diagnostic Tools
POST Error Messages
Error Code
1705-Locked
SCSI Bus
Detected.
System halted.
1730-Fixed Disk
0 does not
support DMA
Mode.
1731-Fixed Disk
1 does not
support DMA
Mode.
1740-Fixed Disk
0 failed Set Block
Mode command
1741-Fixed Disk
1 failed Set Block
Mode command
1750-Fixed Disk
0 failed Identify
command
1751-Fixed Disk
1 failed Identify
command
1760-Fixed Disk
0 does not
support Block
Mode
1761-Fixed Disk
1 does not
support Block
Mode
Continued
Audible
Beeps
Probable Source of Problem
L=Long
S=Short
None
SCSI bus failure.
None
Fixed disk drive error.
None
Fixed disk drive error.
None
Fixed disk drive error.
None
Fixed disk drive error.
None
Fixed disk drive error.
None
Fixed disk drive error.
None
Fixed disk drive error.
None
Fixed disk drive error.
Action
Run Diagnostics. Replace
failed assembly as
indicated.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Run the System
Configuration Utility and
correct.
Continued