Compaq System Configuration Utility Pager Settings
for Booting into Compaq Utilities
Pager Data
Setting
Network IP
address
Network IP
net mask
Network IP
router
address
If you configure the server to boot into Compaq Utilities, it prepares for remote
communications. You can remotely run Diagnostics software, Inspect Utility, or System
Configuration Utility using a workstation running terminal emulation software, such as
Compaq Insight Manager or PC Anywhere.
Booting into the Operating System
When you enable ASR-2 to restart into the operating system and a critical error occurs, ASR-2
logs the error in the Critical Error Log or IML and restarts the server. The system ROM pages
the designated administrator, and executes the normal restart process.
IMPORTANT: When you enable ASR-2 to restart into the operating system,
Modem Dial-In Status, Network Status, and Modem Dial-Out Status are
automatically disabled. In this mode, ASR-2 can page you if a critical error
occurs, but you cannot access the server, and the server cannot dial out to a
remote workstation.
During the recovery process, the ASR-2 feature tries to restart the server up to 10 times. If the
ASR-2 feature cannot restart the server within 10 attempts, it logs a critical error in the
Critical Error Log or IML Log restarts the server into the Compaq Utilities, and puts the
modem into auto-answer mode.
Your System Configuration Utility setting should resemble the following when you enable
ASR to restart into the operating system:
Serial interface
Dial-in status
Dial-out status
Dial-out string
Network status
Continued
Enter the IP address for this server in standard dot notation.
NOTE: This is not used if you select Custom for Network controller.
You must enter your IP address in the NET. CFG file that you load
into the system partition.
Enter the net mask for this server in standard dot notation.
NOTE: This is not used if you select Custom for network controller.
You must enter your IP address in the NET. CFG file that you load
into the system partition.
Enter the router to be used for this server in standard dot notation.
NOTE: This is not used if you select Custom for network controller.
You must enter your IP address in the NET. CFG file that you load
into the system partition.