Pointing Device Interface Test Error Codes - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

Server Manager/R Board Test Error Codes
Error Code
7000-25
7000-26
7000-27
7000-28
7000-33
7000-34
7000-35
7000-41
7000-42
7000-43
7000-44
7000-45
7000-46
7000-51
7000-52
7000-53
7000-54
7000-55
7000-56
7000-57
7000-61
7000-62
7000-78
7000-79

Pointing Device Interface Test Error Codes

The 8600 Diagnostic error codes identifies failures with the pointing device (mouse, trackball,
etc.) or the system board assembly. Corrective action may require replacement of the pointing
device or the system board assembly.
Error Code
8601-xx
Description
Memory Increment
Memory Random Data.
Memory Disturb Address.
Memory HBM.
HBM IO.
HBM BMIC.
HBM Video.
ser_int.
ser_int.
ser_ext.
ser_ext.
ser_ext_int.
ser_ext_int.
mdm_int.
mdm_int.
mdm_ext.
mdm_ext.
mdm_ext_int.
mdm_ext_int.
mdm\c\analog.
Voice/DTMF Internal Loopback.
Voice/DTMF Internal Loopback.
Host ADC Measurements.
Battery.
Pointing Device Interface Test Error Codes
Description
Pointing Device Interface test failed.
Continued
Recommended Action
For error codes 7000-51 through 7000-
57, replace the Server Manager/R board
Enhanced 2400-Baud Integrated Modem
and retest.
For 7000-61 and 7000-62 error codes,
replace the Server Manager/R board
Voice ROM.
For 7000-78 and 7000-79 error codes,
replace the Server Manager/R board
battery.
Table 3-20
Recommended Action
The following steps apply for the 8601-xx
error code:
1. Replace with a working pointing
device and retest.
2. Replace the system board and retest.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
3-41

Hide quick links: