POST Error Messages
Audible
Error Code
Beeps
L=Long
S=Short
1764-Slot x Drive Array - Capacity Expansion Process is
temporarily disabled (followed by one of the following):
Expansion will resume when Array Accelerator has been
reattached.
Expansion will resume when Array Accelerator has been
replaced.
Expansion will resume when Array Accelerator RAM allocation
is successful.
Expansion will resume when Array Accelerator battery reaches
full charge.
Expansion will resume when automatic data recovery has been
completed.
1765-Slot x Drive Array Option ROM Appears to Conflict With
an ISA Card. ISA cards with 16-bit memory cannot be
configured in memory range C0000 to DFFFF along with the
SMART-2/E 8-bit Option ROM due to EISA bus limitations.
Please remove or reconfigure your ISA card.
1766-Slot x Drive Array requires System ROM Upgrade. Run
Systems ROMPaq Utility.
1767-Slot x Drive Array Option ROM is Not Programmed
Correctly or may Conflict with the Memory Address Range of an
ISA Card. Check the Memory Address Configuration of installed
ISA Card(s) or run Options ROMPaq Utility to attempt SMART-
2/E Option ROM Reprogramming.
1768-Slot x Drive
Array -Resuming
logical drive
expansion
process.
Continued
Probable Source of
Problem
None
SMART-2 Controller error
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Action
Reattach or replace Array
Accelerator, wait until the Array
Accelerator batteries have
charged, or for Automatic Data
Recovery to complete, as
indicated.
Remove or reconfigure
conflicting ISA cards. Disable
"shared memory" on any ISA
network cards that may be
installed.
Run the latest Systems
ROMPaq Utility to upgrade your
System ROMs.
Remove or reconfigure
conflicting ISA cards, especially
any cards that are not
recognized by the System
Configuration Utility. Try
reprogramming the SMART-2/E
Controller's ROMs using the
latest Options ROMPaq (version
2.29 or higher).
No action required. Appears
whenever a controller reset or
power cycle occurs while array
expansion is in progress.
Continued
3-15