Compaq ProLiant 1600 Maintenance And Service Manual page 102

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

DAAD Diagnostic Messages
Message
Mirror data
Data was found at reinitialization
miscompare
in the posted write memory;
however, the mirror data
compare test failed resulting in
data being marked as invalid.
Data loss is possible.
Mirrored
Soft errors occurred when
memory
attempting to read the same
location errors
data from both sides of the
mirrored memory. Data loss will
occur.
No
The array accelerator board has
configuration
not been configured.
for Accelerator
Board
Drive (bay) X
The array controller could not
has loose
communicate with this drive at
cable
power-up. This drive has not
previously failed.
Drive (bay) X
This drive has been replaced.
is a
This message displays if a drive
replacement
is replaced in a fault tolerant
drive
logical volume.
Drive (bay) X
This drive has been replaced
is a
and marked OK by the firmware.
replacement
This may occur if a drive has an
drive marked
intermittent failure (for example,
OK
if a drive has previously failed,
then when DAAD is run, the
drive starts working again).
Drive (bay) X
The indicated physical drive has
is failed
failed.
Drive (bay) X
Drive has insufficient capacity to
has insufficient
be used in this logical drive
capacity for its
configuration.
configuration
Drive (bay) X
This drive is being rebuilt from
is undergoing
the corresponding mirror or
drive recovery
parity data.
Continued
Description
Replace the array accelerator board.
Replace the array accelerator board.
If the array accelerator board is present, run
the System Configuration Utility to configure
the board, if desired.
Check all cable connections first. The cables
could be bad, loose, or disconnected. Turn on
the system and attempt to reconnect
data/power cable to the drive. If this does not
work, replace the cable. If that does not work,
the drive may need to be replaced.
If the replacement was intentional, allow the
drive to rebuild.
Replace the drive.
Replace this drive.
Replace this drive with a larger capacity drive.
Normal operations should occur.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Recommended Action