Integrated Management Log - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

3-60
Diagnostic Tools
DAAD Diagnostic Messages
Message
WARNING -
Drive Write
Cache is
enabled on X
Wrong
Accelerator

Integrated Management Log

On servers supporting the Integrated Management Display, Compaq Integrated Management
Log (IML) replaces the Critical Error Log and Correctable Memory Logs. It records system
events and stores them in an easily viewable form. It marks each event with a time-stamp with
one-minute granularity.
Events listed in the Integrated Management Log are categorized as one of four event severity
levels:
Status - indicates that the message is informational only.
Repaired - indicates that corrective action has been taken.
Caution - indicates a non-fatal error condition.
Critical - indicates a component failure.
The Integrated Management Log requires Compaq Operating System-dependent drivers. Refer
to the Compaq Support Software CD for instructions on installing the appropriate drivers.
Continued
Description
Drive has its internal write cache
enabled. The drive may be a
third-party drive or the drive's
operating parameters may have
been altered. Condition may
cause data corruption if power to
the drive is interrupted.
This could mean that either the
board was replaced in the wrong
slot or placed in a system that
was previously configured with
another board type. Included
with this message is a message
indicating the type of adapter
sensed by DAAD and a message
indicating the type of adapter last
configured in EISA nonvolatile
RAM.
Recommended Action
Replace the drive with a Compaq supplied drive,
or restore the drive's operating parameters.
Check the diagnosis screen for other error
messages. Run the System Configuration Utility
to update the system configuration.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents