Compaq ProLiant 1600 Maintenance And Service Manual page 56

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

POST Error Messages
Audible
Error Code
Beeps
L=Long
S=Short
605-Diskette
Drive
Type Error
702-A
coprocessor has
been detected
that was not
reported by
CMOS
703-CMOS
reports a
coprocessor that
has not been
detected
1151-Com Port 1
Address
Assignment
Conflict
1152-Com Port
2, 3, or 4
Address
Assignment
Conflict
1600-Server
Manager/R
Failure
1610-
Temperature
violation
detected.
Waiting for
system
to cool
1611-Fan [fan
description]
failure detected
1611- Fan [fan
description] not
present
Continued
Probable Source of
Problem
2S
Mismatch in drive type.
None
Installed coprocessor not
configured.
2S
Coprocessor or
configuration error.
2S
Both external and internal
serial ports are assigned to
COM1.
2S
Both external and internal
serial ports are assigned to
COM2, COM3 or COM4.
None
Server Manager/R board
failure. Error code displays
after error message.
2S
Ambient system
temperature too hot.
2S
Required fan has failed.
2S
Fan not present.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
3-11
Action
Run the System Configuration
Utility to set diskette type
correctly.
Run the System Configuration
Utility and correct.
1. Run the System
Configuration Utility and
correct.
2. Replace the coprocessor.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run Diagnostics. Replace
failed assembly as indicated.
Check fan in system
environment.
Check fans.
Make sure fans are plugged in.