Critical Error Log Messages
Message
NMI - PCI Bus Parity
Error
NMI - Expansion Board
Error
NMI - Expansion Bus
Master Time-Out
NMI - Expansion Bus
Slave Time-Out
NMI - Fail-Safe Timer
Expiration
Processor Exception
NMI - Processor Parity
Error
Server Manager Failure An error occurred with the Server Manager/R.
NMI - Software
Generated Interrupt
Detected Error
Caution: Temperature
Exceeded
Abnormal Program
Termination
ASR-2 Test Event
NMI- Automatic Server
Recovery Timer
Expiration
Required System Fan
Failure
UPS A/C Line Failure
Shutdown or Battery
Low
ASR-2 detected by
ROM
Continued
A parity error was detected on the PCI bus.
A board on the expansion bus indicated an error condition, resulting in a
server failure.
A bus master expansion board in the indicated slot did not release the bus
after its maximum time, resulting in a server failure.
A board on the expansion bus delayed a bus cycle beyond the maximum
time, resulting in a server failure.
Software was unable to reset the system fail-safe timer, resulting in a
server failure.
The indicated processor exception occurred.
The processor detected a data error, resulting in a server failure.
Software indicated a system error, resulting in a server failure.
The operating system has detected that the temperature of the system has
exceeded the caution level. Accompanying data in the log notes if an auto-
shutdown sequence has been invoked by the operating system.
The operating system has encountered an abnormal situation that has
caused a system failure.
The System Configuration Utility generated a test alert.
The operating system has received notice of an impending ASR-2 timer
expiration.
The required system fan has failed. Accompanying data in the log notes if
an auto-shutdown sequence has been invoked by the operating system.
The UPS notified the operating system that the AC power line has failed.
Accompanying data indicates if an auto-shutdown sequence has been
invoked or if the battery has been nearly depleted.
An ASR-2 activity has been detected and logged by the system ROM.