6500 - 6599, Scsi Hard Drive Test Error Codes; 6600 - 6699, Scsi/Ide Cd-Rom Drive Test Error Codes - Compaq ProLiant ML570 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML570:
Table of Contents

Advertisement

6500 – 6599, SCSI Hard Drive Test Error Codes
The 6500 series of diagnostic error codes identifies failures with SCSI hard drives, SCSI hard
drive controller boards, SCSI hard drive cables, and system board functions. If the system uses a
drive array controller, see "Array Diagnostic Utility " later in this chapter.
Error Code
6500-XX
6502-XX
6505-XX
6506-XX
6509-XX
6523-XX
6528-XX
6600 – 6699, SCSI/IDE CD-ROM Drive Test Error Codes
The 6600 series of diagnostic error codes identifies failures with the CD-ROM drive cables,
CD-ROM drives, adapter boards, or the system board assembly.
Error Code
6600-XX
6605-XX
SCSI Hard Drive Test Error Codes
Description
SCSI disk ID drive types test failed.
SCSI disk unconditional format test
failed.
SCSI disk read test failed.
SCSI disk SA/media test failed.
SCSI disk erase tape test failed.
SCSI disk random read test failed.
Media load/unload test failed.
SCSI/IDE CD-ROM Drive Test Error Codes
Description
CD-ROM ID failed.
CD-ROM read failed.
Diagnostics and Troubleshooting 3-31
Table 3-14
Recommended Action
1.
Run the System Configuration Utility and
verify the drive type.
2.
Replace the SCSI disk drive signal and
power cables, then retest.
3.
Replace the SCSI controller and retest.
4.
Replace the SCSI disk drive and retest.
5.
Replace the system board and retest.
Table 3-15
Recommended Action
1.
Replace the CD-ROM media and retest.
2.
Check and/or replace the signal cable and
retest.
3.
Check the switch settings on the adapter
board (if applicable).
4.
Replace the SCSI controller (if applicable)
and retest.
5.
Replace the CD-ROM drive and retest.
6.
Replace the system board and retest.