Primary Processor Test Error Codes - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

3-26
Diagnostic Tools

Primary Processor Test Error Codes

The 100 series of Diagnostic error codes identifies failures with processor and system board
functions. Corrective action may require replacement of system boards or processor
assemblies (either processor boards or system boards that include the processor).
Error Code
101-xx
104-xx
105-xx
106-xx
107-xx
108-xx
109-xx
110-xx
111-xx
112-xx
113-xx
114-xx
116-xx
122-xx
123-xx
Primary Processor Test Error Codes
Description
CPU test failed
DMA page registers test failed.
Interrupt controller master test
failed.
Port 61 error.
Keyboard controller self-test failed.
CMOS RAM test failed.
CMOS interrupt test failed.
CMOS clock load data test failed.
Programmable timer load data test failed.
Refresh detect test failed.
Speed test slow mode out of range.
Protected mode test failed.
Speaker test failed.
Cache test failed.
Multiprocessor Dispatch test failed.
Interprocessor Communication test failed.
Table 3-2
Recommended Action
Replace the processor board and
retest.
For error codes 103-xx through
106-xx, replace the processor
board and retest.
The following steps apply to error codes
107-xx through 109-xx.
1. Replace the battery/clock module and
retest.
2. Replace the system board and retest.
For error codes 110-xx through 113-xx,
replace the system board and retest.
1. Verify the speaker connection and
retest.
2. Replace the speaker and retest.
3. Replace the system board and retest.
Replace the system board and retest.
The following steps apply to error codes
122-xx
through 123-xx
1. Check the system configuration and
retest.
2. Replace the processor board and
retest.
3. Replace the system board and retest.

Hide quick links: