Fixed Disk Drive Test Error Codes - Compaq ProLiant 1600 Maintenance And Service Manual

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

Fixed Disk Drive Test Error Codes

The 1700 series of Diagnostic error codes identifies failures with fixed disk drives, fixed disk
drive controller boards, fixed disk drive cabling, and system board functions. Corrective action
may require replacement of fixed disk drive cables, fixed disk drive controller boards, fixed
disks, or the system board assembly. If your system uses a drive array controller, see the
section for Drive Array Advanced Diagnostics (DAAD).
Error Code
1700-xx
1701-xx
1702-xx
1703-xx
1704-xx
1705-xx
1708-xx
1709-xx
1710-xx
1715-xx
1716-xx
1717-xx
1719-xx
1736-xx
1799-xx
* Error Checking and Correcting
Fixed Disk Drive Test Error Codes
Description
Fixed disk ID drive types test failed.
Fixed disk format test failed.
Fixed disk read test failed.
Fixed disk write/read/compare test failed.
Fixed disk random seek test failed.
Fixed disk controller test failed.
Fixed disk format bad track test failed.
Fixed disk reset controller test failed.
Fixed disk park head test failed.
Fixed disk head select test failed.
Fixed disk conditional format test failed.
Fixed disk ECC* test failed.
Fixed disk drive power mode test failed.
Drive Monitoring failed.
Invalid fixed disk drive type failed.
Table 3-11
Recommended Action
The following steps apply to error codes
1700-xx through 1799-xx:
1. Run the System Configuration Utility and
verify the drive type.
2. Replace the fixed disk drive signal and
power cables
and retest.
3. Replace the fixed disk drive controller
and retest.
4. Replace the fixed disk drive and retest.
5. Replace the system board and retest.
Compaq ProLiant 1600 Servers Maintenance and Service Guide