Compaq ProLiant 1600 Maintenance And Service Manual page 89

Hide thumbs Also See for ProLiant 1600:
Table of Contents

Advertisement

3-44
Diagnostic Tools
Table 3-21 lists DAAD diagnostic messages in alphabetical order.
Message
Accelerator
board not
detected
Accelerator
error log
Accelerator
parity read
errors: n
Accelerator
parity write
errors: n
Accelerator
status:
Permanently
disabled
Accelerator
status:
Possible data
loss in cache
Accelerator
status:
Temporarily
disabled
DAAD Diagnostic Messages
Description
Array controller did not detect a
configured array accelerator
board.
List of the last 32 parity errors
on transfers to or from memory
on the array accelerator board.
Displays starting memory
address, transfer count, and
operation (read and write).
Number of times that read
memory parity errors were
detected during transfers from
memory on array accelerator
board.
Number of times that write
memory parity errors were
detected during transfers to
memory on the array accelerator
board.
Array accelerator board has
been permanently disabled. It
will remain disabled until it is
reinitialized using the System
Configuration Utility.
Possible data loss detected
during power-up due to all
batteries being below sufficient
voltage level and no presence of
the identification signatures on
the array accelerator board.
Array accelerator board has
been temporarily disabled.
Table 3-21
Recommended Action
Install array accelerator board on array
controller. If an array accelerator board is
installed, check for proper seating on the
array controller board. You may need to run
the System Configuration Utility and disable
the array accelerator board to get this
message off the screen.
If there are many parity errors, you may need
to replace the array accelerator board.
If there are many parity errors, you may need
to replace the array accelerator board.
If there are many parity errors, you may need
to replace the array accelerator board.
Check the Disable Code field. Run the
System Configuration Utility to reinitialize the
array accelerator board.
There is no way to determine if dirty or bad
data was in the cache and is now lost.
Check the Disable Code field.
Continued