DAAD Diagnostic Messages
Message
Drive
The monitor and performance
Monitoring is
features have not been enabled.
NOT enabled
for drive bay X
Drive time-out
DAAD issued a command to a
occurred on
physical drive and the command
physical drive
was never acknowledged.
bay X
Drive (bay) X
Firmware on this physical drive
firmware
is below the latest
needs
recommended version.
upgrading
Drive (bay) X
Physical drive has invalid
has invalid
monitor and performance data.
M&P stamp
Drive X
Message indicates which
indicates
physical drive appears to be
position Y
scrambled or in a drive bay other
than the one for which it was
originally configured.
Drive (bay) X
The copies of the RIS on this
RIS copy
drive do not match.
mismatch
Drive (bay) X
An error occurred while DAAD
upload code
was trying to read the upload
not readable
code information from this drive.
Duplicate write
Data could not be written to the
memory error
array accelerator board in
duplicate due to the detection of
parity errors. This is not a data
loss situation.
Error occurred
An error occurred while DAAD
reading RIS
was trying to read the RIS from
copy from
this drive.
drive (bay) X
FYI: Drive
The installed drive was not
(bay) X is non-
supplied by Compaq.
Compaq
supplied
Continued
Description
Run the System Configuration Utility to
initialize the monitor and performance
features.
The drive or cable may be bad. Check the
other error messages on the Diagnostics
screen to determine resolution.
Run the Options ROMPaq Utility to upgrade
the drive firmware to the latest revision.
Run the System Configuration Utility to
properly initialize this drive.
Examine the graphical drive representation on
DAAD to determine proper drive locations.
Remove drive X and place it in drive position
Y. Rearrange the drives according to the
DAAD instructions.
This drive may need to be replaced. Check for
other errors.
If there were multiple errors, this drive may
need to
be replaced.
Replace the array accelerator board.
If there were multiple errors, this drive may
need to
be replaced.
If problems exist with this drive, replace it with
a
Compaq drive.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Recommended Action
3-53