POST Error Messages
Audible
Error Code
Beeps
L=Long
S=Short
163-Time & Date
Not Set
164-Memory
Size Error
170- Expansion
Device Not
Responding
172-
Configuration
Nonvolatile
Memory Invalid
172-1
Configuration
Nonvolatile
Memory Invalid
172-2 IRC
Configuration
Invalid
173- Slot ID
Mismatch
174-
Configuration/Slo
t Mismatch
Device Not
Found
175-
Configuration/Slo
t Mismatch
Device Found
176-Slot with Not
Readable ID
Yields
Valid ID
177-
Configuration
Not Complete
Continued
Probable Source of
Problem
2S
Invalid time or date in
configuration memory.
2S
Configuration memory
incorrect.
None
EISA or PCI expansion
board failure.
None
Nonvolatile configuration
corrupt or jumper installed.
None
Nonvolatile configuration
corrupt.
None
IRC enabled and video
controller is in PCI slot on
the secondary bus.
None
Board replaced,
configuration not updated.
None
EISA or PCI board not
found.
None
EISA or PCI board added,
configuration not updated.
None
EISA or PCI board in slot
that should contain an ISA
board.
None
Incomplete System
Configuration.
Compaq ProLiant 1600 Servers Maintenance and Service Guide
Action
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Check board for secure
installation. Replace the failed
board if necessary.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Move video controller to a PCI
slot on the primary PCI bus.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
Run the System Configuration
Utility and correct.
3-5