100-199, Primary Processor Test Error Codes

The 100 series of diagnostic error codes identifies failures with processor and system board
functions generated by Compaq Server Diagnostics.
Error Code
101-xx
103-xx
104-xx
105-xx
106-xx
107-xx
108-xx
109-xx
110-xx
111-xx
113-xx
114-xx
116-xx
122-xx
123-xx
199-xx
Primary Processor Test Error Codes
Description
CPU test failed
DMA page registers test failed
Interrupt controller master test
failed
Port 61 error
Keyboard controller self-test failed
CMOS RAM test failed
CMOS interrupt test failed
CMOS clock load data test failed
Programmable timer load data test
failed
Refresh detect test failed
Protected mode test failed
Speaker test failed
Cache test failed
Multiprocessor Dispatch test failed
Interprocessor Communication
test failed
Installed devices test failed
Diagnostics and Troubleshooting 3-27
Table 3-3
Recommended Action
Replace the processor board and retest.
Replace the processor board and retest.
1.
Replace the battery/clock module and retest.
2.
Replace the system board and retest.
Replace the processor board and retest.
1.
Verify the speaker connection and retest.
2.
Replace the speaker and retest.
3.
Replace the system board and retest.
Replace the system board and retest.
1.
Check the system configuration and retest.
2.
Replace the processor board and retest.
3.
Replace the system board and retest.
1.
Check the system configuration and retest.
2.
Verify cable connections and retest.
3.
Check switch and/or jumper settings and retest.
4.
Run the Configuration Utility and retest.
5.
Replace the processor board and retest.
6.
Replace the system board and retest.