Sensor (Booklet Knife Hp) Removal - Lexmark X940e Service Manual

Mfp finisher
Hide thumbs Also See for X940e:
Table of Contents

Advertisement

7510-XXX
5. Remove the booklet rear tamper motor (A).
A
Connector
Left

Sensor (booklet knife HP) removal

1. Remove the booklet unit assembly. See
"Booklet unit assembly removal" on page
4-121.
2. Remove the booklet unit assembly left cover. See
"Booklet unit assembly left cover" on page
4-128.
3. Rotate knife sector gear clockwise until the flag is in the folding sensor position.
4. Remove one screw securing the sensor (knife HP sensor & Knife folding sensor) from the knife frame
assembly.
5. Disconnect the connector from the sensor (booklet knife HP and booklet knife folding).